Large Language Model Prediction of Subsequent Ultrasound BI-RADS Categories from Pre-Imaging Clinical Information in Symptomatic Breast Patients: An Exploratory Retrospective Study.
Authors
Affiliations (5)
Affiliations (5)
- Department of Radiology, Faculty of Medicine, Istanbul Atlas University, Istanbul, Turkiye.
- Department of General Surgery, Faculty of Medicine, Istanbul Atlas University, Istanbul, Turkiye.
- Department of Medical Biochemistry, Faculty of Medicine, Izmir Katip Celebi University, Izmir, Turkiye.
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
- Department of Medical Biochemistry, Faculty of Medicine, Istanbul Atlas University, Istanbul, Turkiye.
Abstract
Artificial intelligence (AI) has shown promising performance in image-based breast lesion analysis, but the ability of large language models (LLMs) to predict subsequent ultrasound (US) BI-RADS categorization from pre-imaging clinical information remains less well characterized. This exploratory study evaluated whether an LLM could predict subsequent US BI-RADS categories using clinical information and whether the addition of physical examination findings altered predictive performance. This retrospective single-center exploratory study included 120 women with breast-related complaints who underwent breast ultrasonography. Two LLM-based workflows were evaluated: a clinical-only workflow and a clinical-plus-physical-examination workflow. US BI-RADS served as the imaging reference outcome. Agreement was assessed using unweighted and quadratic weighted Cohen's κ. Prediction of US BI-RADS ≥4 was evaluated using sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), balanced accuracy, and area under the receiver operating characteristic curve (AUC), with 95% confidence intervals (CIs). The workflows were compared using paired DeLong and McNemar tests. Exploratory predictors of US BI-RADS ≥4 were evaluated using Firth penalized logistic regression. Nine of 120 patients (7.5%) had US BI-RADS ≥4. For the clinical-only workflow, unweighted κ was 0.198 (95% CI, 0.056-0.338) and quadratic weighted κ was 0.304 (95% CI, 0.070-0.500); corresponding values for the clinical-plus-physical-examination workflow were 0.014 (95% CI, -0.105-0.135) and 0.241 (95% CI, 0.034-0.413), respectively. Sensitivity for US BI-RADS ≥4 was 55.6% (95% CI, 21.2-86.3) and 33.3% (95% CI, 7.5-70.1), while NPV was 96.3% (95% CI, 90.8-99.0) and 94.3% (95% CI, 88.0-97.9) for the clinical-only and clinical-plus-physical-examination workflows, respectively. AUCs were 0.748 (95% CI, 0.519-0.977) and 0.643 (95% CI, 0.409-0.877), with no significant difference between workflows (paired DeLong P = 0.291; McNemar P = 0.579). In exploratory Firth regression, the presence of a hard palpable lesion was associated with US BI-RADS ≥4 (adjusted OR, 11.67; 95% CI, 1.77-75.95; P = 0.013). LLM-based prediction from pre-imaging clinical information showed limited agreement with subsequent US BI-RADS categorization. Although the clinical-only workflow had numerically higher performance than the clinical-plus-physical-examination workflow, the difference was not statistically significant. Neither workflow demonstrated sufficient sensitivity to support standalone rule-out, imaging deferral, or clinical triage. These exploratory findings require validation in larger prospective cohorts.