Training AI Models for Automatic Segmentation and Quantification of White Matter Lesions Across Multiple Centres.
Authors
Affiliations (9)
Affiliations (9)
- Ailice Labs, Department of Science, Technology and Society, University School for Advanced Studies IUSS Pavia, 27100 Pavia, Italy.
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, 20122 Milan, Italy.
- Unit of Radiology, IRCCS Galeazzi-Sant'Ambrogio Hospital, 20157 Milan, Italy.
- Department of Life Sciences, Health and Health Professions, Link Campus University, 00165 Rome, Italy.
- DeepTrace Technologies S.R.L., 20122 Milan, Italy.
- Lega Italiana per la Lotta contro i Tumori (LILT) Milano Monza Brianza, 20127 Milan, Italy.
- Department of Engineering for Innovation Medicine, University of Verona, 37129 Verona, Italy.
- Department of Physics ''Giuseppe Occhialini", University of Milan-Bicocca, 20126 Milan, Italy.
- CDI Centro Diagnostico Italiano, 20147 Milan, Italy.
Abstract
<i>Background and Objectives:</i> White matter hyperintensities (WMH) are MRI biomarkers associated with vascular, neurodegenerative, and mixed neurological diseases. Manual WMH segmentation and volume quantification are time-consuming and operator-dependent, making artificial intelligence (AI) an attractive alternative. This study examined how WMH segmentation and volume-quantification performance changed across nested training cohorts with joint increases in participant and annotated-lesion counts. <i>Materials and Methods:</i> More than 18,000 WMH lesions were manually annotated by four expert raters from multicentre 3T FLAIR ADNI patient studies (<i>n</i> = 300: HC = 108, MCI = 108, and AD = 84) (age: 71.44 ± 7.50; education: 16.10 ± 2.37 years; 142 males). Three nnU-Net models were trained on different numbers of annotated lesions (18,034, 11,496, and 4685 lesions). Models' performance was evaluated using the Dice Similarity Coefficient (DSC) with 5-fold cross-validation. We evaluated generalisability on an independent external dataset of <i>n</i> = 62 patients from European and Asian centres using quantitative and qualitative analyses via a neuroradiological 4-point visual rating scale completed by two expert raters. <i>Results:</i> DSC increased with training set size in both the cross-validation datasets (0.64 ± 0.03, 0.68 ± 0.04, and 0.70 ± 0.02) and the external dataset (0.67, 0.73, and 0.75), with statistically significant improvements and good-to-excellent expert-rated segmentation quality (mean score: 3.23). The model trained on 18,034 lesions achieved performance within the range reported for currently available medical devices. <i>Conclusions:</i> Increasing both the number of participants and annotated WMH lesions substantially improves AI-based WMH segmentation and quantification. Training on more than 18,000 lesions produced robust generalisation, expert-rated good-to-excellent segmentation quality, and performance within the range reported for currently available medical devices.