A Central-Vein-Sign-Aware Deep-Learning Pipeline for Lesion Detection and Automated CVS Assessment on Brain SWIp: An Exploratory End-to-End Feasibility Study.

September 28, 2026pubmed logopapers

Authors

Mladenov P,Kellner-Weldon F,Illi CJ,Birbaumer M

Affiliations (2)

  • Institute of Natural Sciences and Humanities, Lucerne School of Engineering and Architecture, Lucerne University of Applied Sciences and Arts, 6048 Horw, Switzerland.
  • Section of Neuroradiology, Department of Radiology and Nuclear Medicine, Neurocenter, Cantonal Hospital Lucerne, University Teaching and Research Hospital, University of Lucerne, 6000 Lucerne, Switzerland.

Abstract

The central vein sign (CVS) is a supportive imaging biomarker for multiple sclerosis (MS), but its manual assessment on susceptibility-weighted imaging with phase enhancement (SWIp) is time-consuming and reader-dependent. Existing automated methods rely on multi-contrast volumetric data and prerequisite lesion masks. We study a deliberately different formulation: a structured end-to-end pipeline operating on a single axial SWIp sequence with sparse slice-wise annotations and no prerequisite volumetric mask, combining anatomical tiling, tiled lesion detection, cross-slice reconstruction of lesion identity, and two complementary branches that independently assess the same lesion crops-direct CVS classification (Pathway A) and vein-presence gating, vein segmentation, and geometric centrality (Pathway B). A cohort of 64 clinical studies annotated by four readers was merged into a consolidated reference. The main contribution is an explicit decomposition of where such a pipeline fails. On an eight-study evaluation, the pipeline recovered 78 of 111 reference lesions (70.3%); lesion-level F1 was 0.667 for Pathway A and 0.706 for Pathway B, rising to 0.785 and 0.818 when restricted to detected lesions, and a paired test found no significant difference between the pathways (p=1.00). Detection is therefore the binding constraint, and a threshold sweep shows the associated overcounting of CVS-positive lesions is not separable from it by detector confidence alone. All operating thresholds were selected on these same eight studies, which were acquired on a single scanner, so the figures are single-centre development-set estimates rather than measures of clinical performance and are likely optimistic. Larger-cohort, acquisition-diverse independent evaluation is required before clinical use.

Topics

Journal Article