Back to all papers

High-Strength Deep Learning Image Reconstruction Versus Adaptive Statistical Iterative Reconstruction for Stenosis Assessment in Stented Coronary Vessels on Coronary CT Angiography: A Multireader Study.

November 20, 2026pubmed logopapers

Authors

Zdanowicz-Ratajczyk A,Korbecki A,Sobański M,Kacała A,Winiarczyk K,Litwinowicz K,Guziński M,Reczuch K

Affiliations (4)

  • Department of General Radiology, Interventional Radiology, and Neuroradiology, Wroclaw Medical University, 50-556 Wrocław, Poland.
  • Department of Radiology, University Clinical Hospital of Jan Mikulicz-Radecki in Wroclaw, 50-556 Wrocław, Poland.
  • Department of Cardiology, Faculty of Medicine, Institute of Heart Diseases, Wroclaw Medical University, 50-556 Wrocław, Poland.
  • Institute of Heart Diseases, University Clinical Hospital in Wroclaw, 50-556 Wrocław, Poland.

Abstract

<b>Background/Objectives:</b> To compare high-strength deep learning image reconstruction (DLIR-H) with adaptive statistical iterative reconstruction (ASIR-V) for coronary computed tomography angiography (CCTA) of stented vessels, evaluating image quality, stenosis measurement accuracy, and classification performance against invasive coronary angiography (ICA) as reference standard. <b>Methods:</b> This retrospective single-centre study included 20 patients (30 coronary vessels) with prior stent implantation and ≥50% stenosis on CCTA. Datasets were reconstructed using ASIR-V and DLIR-H. Four blinded readers assessed subjective image quality and in-stent lumen and vessel stenosis degree; Bayesian hierarchical models accounted for reader and vessel variability. <b>Results:</b> DLIR-H improved subjective noise ratings (posterior probability >99%) and reduced in-stent lumen stenosis measurement error by approximately 15% (estimate: -0.16; 90% credible interval: -0.30 to -0.01; probability: 96%), with no clear evidence of an effect on native-vessel stenosis measurement error (probability: 72%). False-positive stent-level classifications (CAD-RADS ≥4) decreased from 10 to 4 reader assessments, whereas false-negative classifications increased from 2 to 4. Only one stent was reference-positive on ICA. Inter-reader agreement was similar for both reconstructions. <b>Conclusions:</b> In this exploratory study, DLIR-H was associated with a modest reduction in in-stent lumen stenosis measurement error, with no benefit for native vessel stenosis. At the stent level, DLIR-H shifted classifications towards CAD-RADS ≤3 but did not improve classification accuracy. Inter-reader agreement was limited with both reconstructions. Given the small sample and the single stent with ≥70% stenosis on ICA, these findings should be regarded as preliminary and require confirmation before informing routine clinical use.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.