Back to all papers

Deep Learning Reconstruction for High-b-Value FOCUS DWI in Pancreatic Cancer: Image Quality Improvement and Effects on ADC Measurements.

November 17, 2026pubmed logopapers

Authors

Wan C,Wang Y,Zhang L,He R,Chen Y,Yu B,Lu B,Tao L,Lv F,Zhang Z

Affiliations (2)

  • Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.
  • Department of Hepatobiliary Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.

Abstract

<b>Objectives:</b> To evaluate whether deep learning reconstruction (DLR) improves pancreas-referenced image quality in high-b-value field-of-view optimized and constrained undistorted single-shot diffusion-weighted imaging (FOCUS DWI) for pancreatic cancer, and to assess reconstruction-related changes in apparent diffusion coefficient (ADC) measurements in tumor and non-tumorous pancreatic regions. <b>Methods:</b> This prospective single-center study included 68 patients with pathologically confirmed pancreatic cancer who underwent 3.0-T pancreatic MRI. FOCUS DWI was acquired with b values of 0, 1000, 1500, and 2000 s/mm<sup>2</sup> and reconstructed with and without DLR. Quantitative metrics included lesion signal-to-noise ratio (SNR), lesion-to-pancreas contrast-to-noise ratio (CNR), lesion-to-pancreas signal intensity ratio (LP-SIR), and ADC values in tumor regions and non-tumorous pancreatic parenchyma. Two abdominal radiologists independently assessed composite image quality and lesion conspicuity using a 5-point ordinal scale. Paired comparisons were performed with Holm correction across b values. <b>Results:</b> DLR significantly increased lesion SNR and lesion-to-pancreas CNR at b = 1000, 1500, and 2000 s/mm<sup>2</sup> (all Holm-adjusted <i>p</i> < 0.001). Absolute image quality was highest at b = 1000 s/mm<sup>2</sup>, whereas the greatest DLR-related lesion SNR gain occurred at b = 1500 s/mm<sup>2</sup>. LP-SIR remained broadly stable after DLR (Holm-adjusted <i>p</i> = 0.767, 1.000, and 1.000). Tumor regions showed lower ADC values than non-tumorous pancreatic parenchyma across all b values and reconstruction conditions (all <i>p</i> < 0.001), while ADC values did not differ significantly between DLR and non-DLR reconstructions within either region (<i>p</i> = 0.414-0.794). Qualitative scores improved after DLR for both readers at all b values (all Holm-adjusted <i>p</i> < 0.001), with weighted κ ranging from 0.717 to 0.896. <b>Conclusions:</b> DLR improved ROI-based quantitative image-quality metrics and qualitative image assessment in high-b-value pancreatic FOCUS DWI, with the greatest lesion SNR gain at b = 1500 s/mm<sup>2</sup>. No statistically significant reconstruction-related differences in ADC measurements were observed within tumor or non-tumorous pancreatic regions.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.