Predictors of Missing Outputs in AI-Based Fetal CNS Biometry Using SonoCNS: A Real-World Cohort Study.
Authors
Affiliations (2)
Affiliations (2)
- Collegium Medicum, Jan Kochanowski University, 25-369 Kielce, Poland.
- Clinic of Obstetrics and Gynecology, Provincial Combined Hospital in Kielce, 25-736 Kielce, Poland.
Abstract
<b>Background:</b> Artificial intelligence (AI)-based automated fetal central nervous system (CNS) biometry using SonoCNS may streamline ultrasound assessment, but missing outputs occur in clinical practice. This study aimed to quantify the frequency and patterns of missing SonoCNS measurements across two separately acquired fetal head volumes and to investigate their associations with gestational age, operator, fetal presentation, and fetal biometric characteristics. <b>Methods:</b> This single-center retrospective secondary analysis used prospectively collected data from 385 women examined between 1 May 2022 and 31 May 2023. Each participant underwent second- or third-trimester ultrasound assessment with SonoCNS measurements obtained from two separately acquired volumes (a1, a2) for BPD, HC, OFD, cisterna magna (CM), lateral ventricular atrial width (Vp), and transverse cerebellar diameter (Cereb). Primary endpoints (full set: BPD/HC/OFD/CM/Vp/Cereb) were persistent AI failure (the same parameter missing in both acquisitions for at least one of the six parameters) and AI instability (missing ≥1 parameter in ≥1 acquisition). Structure-specific models assessed miss_CM, miss_Vp, and miss_Cereb. Logistic regression adjusted for operator, fetal presentation, gravidity/parity, and GA-adjusted fetal size residual z-scores (EFW-, HC-, and BPD-for-GA); sensitivity analyses were restricted to AZZ and to examinations at <28 weeks, and an additional full-cohort analysis modeled GA continuously. <b>Results:</b> Persistent AI failure occurred in 23.9% (92/385) and AI instability in 50.4% (194/385); CNS-structure instability occurred in 49.9% (192/385). Structure-specific instability was highest for Vp (34.0%), followed by Cereb (27.3%) and CM (23.4%). Compared with <28 weeks, examinations at ≥28 weeks had higher odds of full-set instability (crude OR 9.81), CNS instability (crude OR 10.13), and missing Vp outputs (crude OR 18.54; all <i>p</i> < 0.001). In multivariable models, the corresponding adjusted ORs were 9.61 (95% CI 4.55-20.28), 9.62 (4.57-20.27), and 21.29 (10.25-44.22), respectively (all <i>p</i> < 0.001). These associations persisted in AZZ-only analyses. Examinations performed by JM were associated with lower CM/Cereb instability and persistent failure, although operator comparisons were limited by the absence of JM examinations at ≥28 weeks. <b>Conclusions:</b> Missing SonoCNS outputs were common across two acquisitions. Later gestational age was associated with greater output instability, particularly for lateral ventricular atrial width, but not with persistent failure after adjustment. Operator-associated differences were observed for selected endpoints; however, their interpretation is limited by the unequal gestational age distribution and the absence of objective acquisition-quality assessment.