Back to all papers

A Parsimonious Machine Learning Model for Predicting Invasive Coronary Angiography Referral After Coronary Computed Tomography Angiography: Development and Multicentre External Validation.

October 2, 2026pubmed logopapers

Authors

Chunta A,Gilbert C,Labib D,Amakiri A,Feng Y,Alavi Fili A,Chew D,Chow BJ,Graham M,Garcia J,Bento M,White J,Miller RJ

Affiliations (4)

  • Departments of Radiology and Cardiac Sciences, Libin Cardiovascular Institute, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 4Z6, Canada.
  • Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, Calgary, AB T2N 4Z6, Canada.
  • Department of Medicine (Division of Cardiology and Nuclear Medicine), University of Ottawa Heart Institute, Ottawa, ON K1Y 4W7, Canada.
  • Department of Medicine and Mazankowski Heart Centre, University of Alberta, Edmonton, AB T6G 0M9, Canada.

Abstract

<b>Background/Objectives:</b> Coronary computed tomography angiography (CCTA) is recommended as a first-line test for suspected coronary artery disease. Many patients undergo invasive coronary angiography (ICA) after CCTA, and no prediction model exists to estimate the probability of this downstream testing. We aimed to develop and validate a parsimonious extreme gradient boosting (XGB) model for predicting ICA referral after CCTA. <b>Methods:</b> Adults undergoing a CCTA were identified at three Canadian centres. An XGB model was trained on 156 variables in the internal cohort (Calgary, <i>n</i> = 8823) and tested in an external cohort (Edmonton, <i>n</i> = 10,596). The full model and a reduced 15-variable model were compared using discrimination and calibration. <b>Results:</b> ICA referral occurred in 1161 (13.2%) internal and 1269 (12.0%) external patients. Internally, the reduced model matched the full model (AUC 0.698 vs. 0.701; <i>p</i> = 0.16) with equivalent calibration (Brier 0.1077 vs. 0.1076; slope 1.21 vs. 1.18). Externally, the full model retained a small but significant advantage (AUC 0.701 vs. 0.687; <i>p</i> < 0.001). Age, anginal nitrate use, and lowest HDL cholesterol were the strongest predictors. <b>Conclusions:</b> A 15-variable XGB model preserved most of the predictive performance of a 156-variable model for ICA referral after CCTA. Clinical use would require evidence that it improves patient selection for ICA.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.