Mask-Guided Two-Stage Synthesis and Regional Quantitative Evaluation of Virtual Contrast-Enhanced Thoracic CT.
Authors
Affiliations (6)
Affiliations (6)
- Program in Bio-Medical Science, Graduate School, Korea University, Sejong 30019, Republic of Korea.
- Department of Radiology, Korea University Anam Hospital, Seoul 02841, Republic of Korea.
- Department of Applied Physics, Graduate School, Korea University, Sejong 30019, Republic of Korea.
- Division of Display and Semiconductor Physics, Korea University, Sejong 30019, Republic of Korea.
- Department of Radiation Oncology, Kangwon National University Hospital, Chuncheon 24289, Republic of Korea.
- Institute of Human Convergence Health Science, Gachon University, Incheon 21936, Republic of Korea.
Abstract
<b>Background/Objectives:</b> Virtual contrast-enhanced CT (vCECT) synthesis may support imaging workflows when iodinated contrast administration is undesirable. However, whole-image similarity can obscure errors in localized vascular enhancement. We evaluated a mask-guided two-stage framework that couples spatially targeted enhancement with separate assessment of localization and synthesis. <b>Methods:</b> This retrospective study included 50 patients with 2550 paired thoracic non-enhanced CT (NECT) and contrast-enhanced CT (CECT) slices from radiotherapy simulation. Stage 1 predicted a contrast-region mask from NECT; Stage 2 used this mask to guide residual synthesis, trained with locally blended pseudo-contrast targets. Localization was assessed using segmentation metrics, and synthesis was evaluated against reference CECT over the whole image and reference-mask regions of interest (ROIs). Ablations compared single-stage residual synthesis, predicted-mask guidance, and reference-mask guidance. <b>Results:</b> Mask prediction achieved a mean Dice similarity coefficient (DSC) of 0.91. Whole-image peak signal-to-noise ratio (PSNR) and structural similarity index were 46.91 dB and 0.96, respectively; ROI values were 34.22 dB and 0.95. Compared with single-stage synthesis, predicted-mask guidance increased ROI PSNR from 18.97 to 34.22 dB and reduced normalized root mean squared error from 0.12 to 0.03. Reference-mask guidance achieved an ROI PSNR of 36.13 dB. <b>Conclusions:</b> Explicit localization improved regional synthesis fidelity in this cohort. The framework links localized CT enhancement to quantitative image-quality evaluation; external and reader-based validation remain necessary before clinical use.