Machine-Learning Prediction of Pediatric Thyroid Nodule Malignancy Using Structured Nodule and Cervical Lymph-Node Ultrasonographic Features.
Authors
Affiliations (2)
Affiliations (2)
- Department of Interventional Medicine, National Center for Children's Health (Beijing), Beijing Children's Hospital, Capital Medical University, No. 56 Nanlishi Road, Xicheng District, Beijing 100045, China.
- Department of Otolaryngology, Head and Neck Surgery, National Center for Children's Health (Beijing), Beijing Children's Hospital, Capital Medical University, No. 56 Nanlishi Road, Xicheng District, Beijing 100045, China.
Abstract
<b>Background/Objectives:</b> Pediatric thyroid nodules carry a higher malignancy risk and more frequent regional cervical lymph-node involvement than adult nodules, making individualized pre-biopsy risk assessment particularly important. We aimed to develop and temporally validate a machine-learning model integrating routinely available thyroid-nodule and cervical lymph-node ultrasonographic features for malignancy-risk estimation in children. <b>Methods:</b> This retrospective single-center study at a tertiary pediatric referral center included consecutive patients aged 18 years or younger undergoing biopsy-based diagnostic evaluation between January 2019 and August 2025. The cohort comprised 195 patients with 221 nodules. Six candidate algorithms were evaluated using patient-grouped nested cross-validation. The selected XGBoost model integrated structured nodule and regional cervical lymph-node ultrasonographic features and was evaluated using discrimination, precision-recall performance, probability accuracy, calibration, and threshold-dependent operating characteristics. ACR TI-RADS served as a secondary standardized comparator. <b>Results:</b> Overall, 151 of 221 nodules (68.3%) were malignant, including 32 of 48 nodules (66.7%) in the temporal validation cohort. The final model achieved an AUROC of 0.973 (95% CI, 0.919-1.000), an AUPRC of 0.986 (95% CI, 0.954-1.000), a Brier score of 0.071 (95% CI, 0.030-0.126), a sensitivity of 84.4%, and a specificity of 87.5%. For comparison, the ACR TI-RADS total score yielded an AUROC of 0.906, while the TR5-positive and TR4/5-positive strategies yielded sensitivities of 84.4% and 93.8% and specificities of 87.5% and 56.2%, respectively. <b>Conclusions:</b> Integrating thyroid-nodule and cervical lymph-node ultrasonographic features enabled individualized malignancy-risk estimation in this selected pediatric biopsy-evaluation cohort. The continuous risk estimate may complement established sonographic assessment as an adjunct to comprehensive diagnostic evaluation. Prospective multicenter external validation is required before broader clinical application.