Back to all papers

Zero-Shot Domain Adaptation of 2D Mammography Lesion Detection Model for 3D Breast CT Malignancy Detection.

August 11, 2026pubmed logopapers

Authors

Leynes AP,Saenger JA,Weber A,Frauenfelder T,Boss A

Affiliations (3)

  • Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich, 8091 Zurich, Switzerland.
  • b-rayZ, 8952 Schlieren, Switzerland.
  • Institute of Diagnostic and Interventional Radiology, GZO Regional Health Center, 8620 Wetzikon, Switzerland.

Abstract

<b>Purpose</b>: Breast cancer screening relies primarily on two-dimensional (2D) digital mammography, which is limited by tissue superposition and compression-related patient discomfort. Dedicated spiral breast computed tomography (BCT) overcomes these limitations by providing isotropic, fully three-dimensional (3D) volumetric images without compression. However, translating artificial intelligence (AI) advancements to 3D BCT lesion detection is hindered by the scarcity of large-scale annotated 3D datasets and substantial computational constraints. The purpose of this study is to evaluate the feasibility of repurposing a pre-trained 2D mammography AI model for 3D BCT malignancy detection without dedicated model retraining. <b>Methods</b>: In this exploratory proof-of-concept study, the dataset comprised BCT examinations of female patients with malignant lesions. We developed a slab projection framework that systematically rotates the BCT volume and extracts overlapping tissue slabs to simulate mammography-like 2D images compatible with the input requirements of the pre-existing 2D mammography model. The 2D inferences were subsequently back-projected to their original 3D spatial coordinates and aggregated via a consensus voting scheme. Optimization and performance evaluation were performed on the same dataset to establish an internal baseline. Object-level detection performance was assessed using the F1 score, and segmentation quality was evaluated using the Dice coefficient. <b>Results</b>: Application of the proposed framework enabled 3D lesion localization in BCT volumes without requiring domain-specific training. An optimal configuration was found with a sparser angular sampling combined with medium slab thickness (45° angular spacing, 50-voxel thickness), which achieved an F1 score of 0.346, with 48.3% precision and 26.9% recall. Evaluation of segmentation quality corroborated these findings, yielding a maximum mean Dice coefficient of 0.336 for the 45°/30-voxel configuration. <b>Conclusions</b>: This exploratory proof-of-concept demonstrates the technical feasibility of adapting a pre-trained 2D mammography AI model to volumetric BCT without architectural modifications or retraining. The reported performance represents an internal same-dataset baseline under substantial domain shift and should not be interpreted as generalizable or clinically deployable performance. These findings provide a foundation for future domain-adapted models and independent external validation of AI-based tumour detection in breast CT.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.