Back to all papers

A deep learning model for preoperative differentiation of uterine adenomyoma and uterine leiomyoma on transvaginal ultrasound.

November 12, 2026pubmed logopapers

Authors

Sheng P,Wang J,Lu Q,Zeng Z,Lai X,Yang L,Wang J

Affiliations (3)

  • School of Medical Technology and Information Engineering, Zhejiang Chinese Medical University, Hangzhou, China.
  • Key Laboratory of Reproductive Dysfunction Management of Zhejiang Province, Department of Obstetrics and Gynecology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China.
  • Department of Ultrasound in Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China.

Abstract

To develop and validate a deep learning model for the preoperative differentiation of uterine adenomyoma and uterine leiomyoma on transvaginal ultrasound. This retrospective study included 207 transvaginal ultrasound images from 98 patients between January 2020 and January 2025, split at the patient level into a training set (68 patients, 140 images) and an independent test set (30 patients, 67 images). A comparative framework was established: (1) radiomics models; (2) standard deep learning models; and (3) the proposed ResNet-50 model enhanced with the channel-aware feature modulation module. Three gynecologic ultrasonographers independently reviewed the test images for comparison with model performance. Model performance was evaluated using accuracy, precision, sensitivity, specificity, F1-score, and the area under the receiver operating characteristic curve (AUC). Exploratory explainability analyses used SHAP for the best-performing radiomics model and Grad-CAM for the proposed model. On the patient-level test set, the proposed model showed favorable numerical performance among the evaluated models, with an accuracy of 0.833, F1-score of 0.800, and AUC of 0.855 (95% CI: 0.693-0.982). The best-performing radiomics model, Logistic Regression, achieved a patient-level accuracy of 0.667 and AUC of 0.814 (95% CI: 0.630-0.962). The proposed model showed numerically higher accuracy than the three readers. SHAP summarized the contributions of radiomic features, whereas Grad-CAM visualized image regions associated with model predictions. The proposed model showed promising internal test performance for differentiating uterine adenomyoma from uterine leiomyoma on transvaginal ultrasound and may serve as a potential decision-support approach, warranting external and prospective validation.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.