Back to all papers

Clinical Plausibility and Pretraining Utility of Virtual Narrow-Band Imaging for Laryngeal Lesion Classification: Multicenter Model Development and Validation Study.

November 26, 2026pubmed logopapers

Authors

Huang JL,Li LJ,Wang ML,Zhu JQ,Dou LZ,Liu YM,Zhao YD,Zhang X,Ni XG

Affiliations (3)

  • Department of Endoscopy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 17 Panjiayuan South Lane, Chaoyang District, Beijing, 100021, China, 86 10 8778 7606.
  • Department of Otorhinolaryngology, The People's Hospital of Wenshan Prefecture, Wenshan, Yunnan, China.
  • Department of Endoscopy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China.

Abstract

Pathology-labeled optical narrow-band imaging (NBI) is difficult to assemble for laryngeal lesion classification. Translating existing white-light imaging (WLI) into virtual NBI (Vir-NBI) may improve learning from limited real-NBI data, but its value beyond that of the original images is uncertain. This study aimed to determine whether Vir-NBI pretraining improves real-NBI classification or label efficiency compared with pretraining on the same pathology-labeled WLI. This multicenter study compared ResNet-50 classifiers pretrained on pathology-labeled WLI or paired Vir-NBI images generated by a frozen, region-of-interest-guided CycleGAN (cycle-consistent generative adversarial network). The primary outcome was the image-level area under the receiver operating characteristic curve (AUC) difference (Vir-NBI minus WLI). Label efficiency was evaluated in these external cohorts with 10 to 100 labeled real-NBI patients and 25 paired training runs per sample size. Color-matched augmentation and paired test-modality analyses examined the influence of color change and test modality. Prospective temporal validation and a 12-clinician assessment evaluated patient-level performance and perceived image quality. The CHCAMS (National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College) cohort comprised 1245 patients with 8476 paired WLI-Vir-NBI images. External validation included 182 patients from CHSZCAMS (Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College) and 129 from People's Hospital of Wenshan Prefecture (WSPH). External image-level AUCs were 0.806 with WLI and 0.787 with Vir-NBI (difference -0.019, 95% CI -0.047 to 0.008; <i>P</i>=.17). With 10 labeled real-NBI patients, external patient-level AUCs were 0.843 and 0.773, respectively (difference -0.070, 95% CI -0.116 to -0.029; Holm-adjusted <i>P</i>=.006). The normalized area-under-the-learning-curve difference across 10 to 100 patients favored WLI (-0.049, 95% CI -0.090 to -0.011; Holm-adjusted <i>P</i>=.01). Color-matched WLI augmentation yielded higher external image-level AUC than with Vir-NBI (0.774 vs 0.739; difference 0.036, unadjusted 95% CI 0.004-0.070). In the 58-case examination-linked cohort, relative Vir-NBI performance improved on translated test images (primary-model interaction 0.235, unadjusted 95% CI 0.080-0.390); fixed-duration and all-view sensitivity analyses had case-level CIs that included 0. In the CHCAMS prospective validation cohort (138 patients), patient-level AUCs were 0.846 (95% CI 0.775-0.910) and 0.844 (95% CI 0.777-0.905), respectively. WLI identified 90.9% (60/66) of high-risk patients, compared with 81.8% (54/66) with Vir-NBI, reflecting 6 discordant patients (exact McNemar <i>P</i>=.03; Holm-adjusted <i>P</i>=.06). Among 100 image pairs from the CHCAMS source cohort, clinicians rated plausibility as 4 to 5 in 86.9% (1043/1200) of ratings; intraclass correlation coefficients for the mean ratings of 12 clinicians ranged from 0.398 (95% CI 0.265-0.497) to 0.583 (95% CI 0.471-0.659). Vir-NBI pretraining did not demonstrate incremental value over WLI for real-NBI classification. External learning curves favored WLI with small real-NBI training sets. Test-domain dependence suggests that compatibility with real-NBI may contribute to performance differences.

Topics

Narrow Band ImagingLaryngeal NeoplasmsJournal ArticleMulticenter StudyValidation Study

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.