Agreement between AI-based automated and expert-defined manual whole-body tumor volume assessment in [¹⁸F]FDG-PET/CT of NSCLC patients.
Authors
Affiliations (8)
Affiliations (8)
- Department of Radiology, LMU University Hospital, LMU Munich, Marchioninistraße 15, 81377, Munich, Germany. [email protected].
- Department of Radiology, LMU University Hospital, LMU Munich, Marchioninistraße 15, 81377, Munich, Germany.
- Comprehensive Pneumology Center (CPC-M), Member of the German Center for Lung Research (DZL), Munich, Germany.
- Department of Radiology, Asklepios Lung Clinic Gauting, Munich, Germany.
- Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Munich, Germany.
- Department of Pneumology, LMU University Hospital, LMU Munich, Munich, Germany.
- Munich Center for Machine Learning (MCML), Munich, Germany.
- Division of Nuclear Medicine and Molecular Imaging, The Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Abstract
Whole-body tumor burden is an emerging biomarker for disease assessment and response monitoring in PET/CT, and automated approaches may enable standardized, observer-independent quantification. Automated and expert-defined tumor volumes differ in their delineation, and their agreement remains unclear. This method-comparison study evaluated the agreement between threshold-based AI volumetric PET metrics and expert-defined manual whole-body tumor volumes at baseline and during treatment. In this retrospective single-center study, [¹⁸F]FDG-PET/CT examinations from 118 patients with histologically confirmed NSCLC were analyzed, comprising 118 baseline and 278 follow-up examinations (n = 396). Manual whole-body tumor segmentation was compared with automated metrics (TMTV41%, TMTVSUV4) from CE-marked software. Agreement was assessed using Lin's concordance correlation coefficient (CCC), Bland-Altman analysis, coverage probability within predefined relative limits, agreement on the presence of measurable tumor burden, and agreement in the change from baseline. All follow-up examinations were included in a secondary analysis accounting for repeated examinations within patients. At baseline, CCC was 0.94 (95% CI 0.74-0.95) for TMTVSUV4 and 0.81 (0.35-0.86) for TMTV41%, with wide and asymmetric intervals. Concordance was lower at the first follow-up (0.74 and 0.40) and across all follow-up examinations (0.59 and 0.40). On the ratio scale, automated measurements deviated at the first follow-up, with geometric mean ratios of 1.46 (95% CI 1.19-1.79) for TMTV41% and 0.37 (0.29-0.48) for TMTVSUV4. Coverage probability within ± 20% of the manual reference was 26.3% for both metrics at baseline and 11.1% and 13.7% at the first follow-up. TMTVSUV4 returned a volume of zero in 28 of 278 follow-up examinations in which the expert reference remained positive. Agreement in the relative change from baseline was low (CCC 0.08 for TMTV41% and 0.44 for TMTVSUV4), and agreement in exploratory response categories defined by a ± 30% change in tumor volume was only fair (Cohen's κ 0.32 and 0.35). Automated threshold-based PET volumetry reflects overall tumor burden but is not interchangeable with anatomically guided expert delineation. Agreement is lower during treatment and is only fair when the change from baseline is classified into response categories, supporting the use of AI-based volumetry as a complementary tool rather than a replacement for expert assessment.