Back to all papers

Influence of dominant sequence artifacts on generative AI for virtual contrast-enhancement in breast MRI.

November 3, 2026pubmed logopapers

Authors

Brock L,Markale A,Nguyen TT,Metz M,George A,Heidarikahkesh S,Schreiter H,Pfann Hossbach J,Kapsner LA,Ohlmeyer S,Wenkel E,Uder M,Laun FB,Knoll F,Bickelhaupt S

Affiliations (8)

  • Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054, Erlangen, Germany. [email protected].
  • Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander- Universität Erlangen-Nürnberg, Erlangen, Germany. [email protected].
  • Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054, Erlangen, Germany.
  • Institute of Computer Science, Polish Academy of Science, Warsaw, Poland.
  • Department for Computer Science 5 (Pattern Recognition), Friedrich-Alexander-University Erlangen-Nuremberg (FAU), Martensstrasse 3, 91058, Erlangen, Germany.
  • Medical Informatics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
  • Diagnostische Radiologie, Radiologie München, München, Germany.
  • Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander- Universität Erlangen-Nürnberg, Erlangen, Germany.

Abstract

Virtual contrast-enhanced (vCE) breast MRI is a deep learning approach for generating contrast-like images from non-contrast acquisitions. As diffusion-weighted imaging (DWI) has emerged as a major contributor to enhancement synthesis, understanding the influence of DWI-related image artifacts is important for the robustness and potential clinical implementation of AI-based contrast-free imaging approaches. We evaluated the robustness of a pix2pix-based vCE synthesis model to artifact-contaminated DWI during training and inference. This IRB-approved, retrospective study included 1,974 multiparametric breast MRI examinations (mean age: 49 years) acquired with two clinical routine 3T MRI scanners (2017-2022). High b-value (b = 1500 s/mm<sup>2</sup>) DWI images were automatically classified for high-intensity (HI) and low-intensity (LI) artifacts using a pretrained neural network. A pix2pix 2D-GAN was trained either after excluding artifact-affected slices (vCE-clean) or using all available slices (vCE-all). Performance was evaluated using image similarity metrics, lesion-based analysis, reader assessment, and correlation of artifact scores with reconstruction errors. Excluding artifact-affected slices during training resulted in a small but statistically significant increase in whole-image structural similarity index (SSIM) with small effect size (vCE-all 0.843 ± 0.034; vCE-clean 0.849 ± 0.031, p < 0.001, d<sub>av</sub> = 0.20). However, lesion-based metrics and qualitative ratings of lesion enhancement and image quality were comparable between models. During Inference, strong LI DWI artifacts were associated with higher lesion-based errors. Controlling for artifacts on diffusion weighted imaging (DWI) during vCE training only minorly influenced technical metrics but not perceived image quality/lesion enhancement. In contrast, severe signal-loss artifacts during inference impaired local performance, highlighting the importance of image quality control during potential deployment.

Topics

ArtifactsDiffusion Magnetic Resonance ImagingBreast NeoplasmsBreastMagnetic Resonance ImagingJournal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.