Back to all papers

Investigation of S-Detect AI (a computer-aided diagnosis tool) versus ultrasound operators for thyroid nodule classification using British Thyroid Association guidelines: A pilot diagnostic accuracy study.

September 3, 2026pubmed logopapers

Authors

Walker K,Michael J,Ballard M,Chilvers G,Colley S,Hussain K,Rickard L

Affiliations (2)

  • University Hospitals Birmingham NHS Foundation Trust, UK.
  • Birmingham City University, UK.

Abstract

Thyroid nodules affect more than 60% of the population, approximately 5% being malignant. The British Thyroid Association U-classification guides ultrasound risk stratification across the United Kingdom but is subject to inter-observer variability. Artificial intelligence decision support tools may offer more standardised assessment, yet no peer-reviewed study has validated S-Detect, a computer-aided diagnosis tool integrated into Samsung ultrasound systems, against the British Thyroid Association framework. This study compares S-Detect with experienced ultrasound operators using histology as the reference standard. This retrospective pilot diagnostic accuracy study assessed 32 thyroid nodules (September 2023 to August 2024). S-Detect served as the index test applied retrospectively on a Samsung RS85 Prestige platform; prospectively assigned U-scores were the comparator and surgical histology the reference standard. A secondary analysis varied Doppler input across all four options in the 11 malignancies misclassified by S-Detect to test whether Doppler selection contributed to misclassification. Operators achieved superior balanced performance (sensitivity: 78.9%, specificity: 84.6%, accuracy: 81.3%, and area under the curve: 0.870) compared with S-Detect (42.1%, 100%, 65.6%, area under the curve: 0.729), which under-classified 58% of malignancies. Inter-method agreement was slight (<i>κ</i> = 0.175), with significant directional discordance (McNemar <i>p</i> = 0.008). Doppler manipulation produced substantial variability: 81.8% of misclassified cases showed U-score change attributable solely to Doppler selection, with peripheral patterns yielding zero correct malignancy classifications. Operators achieved superior diagnostic performance. S-Detect's high false-negative rate appears largely driven by over-reliance on Doppler. Its clinical utility is limited within this single-centre study. Future iterations excluding Doppler would likely achieve substantially improved sensitivity.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.