Back to all papers

Improved upper abdominal MRI with VIBE sequences using deep learning-supported k-space sampling in a cohort undergoing MRI for gynecologic diseases.

September 21, 2026pubmed logopapers

Authors

Malec K,Heimer J,Marketin A,Nickel D,Weiland E,Kubik-Huch RA,Hausmann D

Affiliations (3)

  • Department of Radiology, Kantonsspital Baden, affiliated Hospital for Research and Teaching of the Faculty of Medicine of the University of Zurich, Baden, Switzerland.
  • Research & Clinical Translation, Magnetic Resonance, Siemens Healthineers AG, Erlangen, Germany.
  • Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Mannheim, Germany.

Abstract

BackgroundVolumetric interpolated breath-hold examination (VIBE) is widely used in upper abdominal MRI but can be limited by low signal-to-noise ratio (SNR), especially when rapid acquisition is prioritized. Deep learning (DL)-enhanced reconstruction may improve image quality without extending acquisition time.PurposeTo compare subjective image quality, artifacts, noise, and estimated SNR and contrast-to-noise ratio (CNR) between DL-supported and standard (ST) VIBE sequences of the upper abdomen in women undergoing pelvic MRI, including the effect of contrast enhancement.Material and MethodsThis prospective study included 60 women (mean age 42.1 ± 14.7 years). Four axial sequence types were evaluated: ST and DL VIBE, both non-contrast (NC) and contrast-enhanced (CE). Three radiologists rated image quality, artifacts, and noise using a standardized 4-point Likert scale. Interobserver agreement and the effects of age and body mass index (BMI) were assessed. A quantitative region-of-interest (ROI)-based SNR/CNR analysis was also performed.ResultsDL VIBE yielded better image quality, fewer artifacts, and less noise than ST VIBE. DL-by-CE interactions were significant for image quality and artifacts. Interobserver agreement was moderate for image quality and artifacts but low for noise. Quantitative analysis showed no significant differences in estimated SNR or CNR between ST and DL VIBE before or after contrast administration (all <i>p</i> ≥ 0.35).ConclusionDL VIBE improves image quality and reduces artifacts, particularly in NC imaging.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.