Back to all papers

Opportunistic Screening of Carotid Atherosclerosis and Cardiovascular Mortality Risk Using Chest Radiographs: A Comparative Study of Foundation Models.

August 20, 2026pubmed logopapers

Authors

Rehman A,Kim J,Lee H,Chang J,Park SM

Affiliations (3)

  • Department of Biomedical Sciences Seoul National University Graduate School Seoul South Korea.
  • XAIMED Co. Ltd Seoul South Korea.
  • Department of Family Medicine Seoul National University Hospital Seoul South Korea.

Abstract

Cardiovascular disease (CVD) remains a leading cause of death, but population-level screening for atherosclerosis often depends on specialized imaging that is not routinely available. We evaluated foundation models for opportunistic detection of carotid atherosclerosis from chest radiographs, assessed the prognostic value of the resulting biomarker for CVD death, and examined model explainability. Among 5785 participants with carotid sonography annotations, we compared Rad-DINO, DINOv2, OpenCLIP, and CheXagent for chest radiograph-based atherosclerosis detection using linear probing, selective fine-tuning, and low-rank adaptation. Performance was assessed by area under the receiver operating characteristic curve with 95% CIs. Explainability was evaluated using gradient-weighted class activation mapping and a clinical relevance index, which quantified attention within cardiovascular anatomic masks. The selected model generated a Deep-Learning Chest X-Ray Atherosclerosis Score, which was tested for association with CVD death in 32 524 participants using Framingham Risk Score-adjusted Cox models. Rad-DINO achieved the highest performance with selective fine-tuning (area under the receiver operating characteristic curve, 0.74 [95% CI, 0.71-0.77]) and low-rank adaptation (area under the receiver operating characteristic curve, 0.74 [95% CI, 0.70-0.76]), with the highest anatomic relevance under low-rank adaptation (clinical relevance index, 0.31). Higher Deep-Learning Chest X-Ray Atherosclerosis Score tertiles were strongly associated with CVD death (adjusted hazard ratio, 9.36 [95% CI, 3.35-26.15] for high versus low; <i>P</i>-trend<0.005). The model concordance index was 0.73 (95% CI, 0.67-0.75). Foundation models enable opportunistic detection of carotid atherosclerosis from chest radiographs and yield a biomarker that provides prognostic information for CVD death. Explainability analyses demonstrated alignment with CVD anatomic regions, supporting clinical relevance and scalable risk stratification.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.