AI-integrated versus Standard Mammography Screening Pathways: A Systematic Review and Network Meta-Analysis of Diagnostic Accuracy.
Authors
Affiliations (11)
Affiliations (11)
- Department of Medical Education, Taipei Veterans General Hospital, Taipei, Taiwan.
- School of Medicine, National Yang-Ming Chiao Tung University, Taipei, Taiwan.
- Institute of Biophotonics, National Yang-Ming Chiao Tung University, No. 155, Sec. 2, Linong St, Beitou District, Taipei 112304, Taiwan.
- Department of Computer Science, Whiting School of Engineering, Johns Hopkins University, Baltimore, Md.
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan.
- Wolfson Centre for Prevention of Stroke and Dementia, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
- Institute of Clinical Medicine, National Yang-Ming Chiao Tung University, Taipei, Taiwan.
- Comprehensive Breast Health Center, Taipei Veterans General Hospital, Taipei, Taiwan.
- Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan.
- Institute of Health Data Analytics and Statistics, College of Public Health, National Taiwan University, Taipei, Taiwan.
- Center for Smart Health and Medicine, Taipei City Hospital, Taipei, Taiwan.
Abstract
Purpose To compare the diagnostic accuracy of artificial intelligence (AI)-integrated and standard mammography screening pathways for breast cancer detection using Bayesian network meta-analysis. Materials and Methods This prospectively registered review searched PubMed, Embase, and Web of Science through March 20, 2026, for diagnostic accuracy studies comparing two or more human-only or AI-integrated screening pathways using digital mammography or tomosynthesis. Bayesian bivariate random-effects network meta-analyses were fitted to a primary four-node and a secondary six-node network; risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies 3 (QUADAS-3) and QUADAS-C tools, and certainty was graded using the Grading of Recommendations Assessment, Development and Evaluation approach. Results Thirty-eight studies, with more than 4.2 million examinations, were included. In the primary digital mammography network (15 studies), AI as an independent reader (sensitivity, 78.9%; specificity, 95.8%) performed similarly to double human reading (sensitivity, 77.7%; specificity, 96.2%). In the secondary network, AI reader assistance had the highest sensitivity (86.8%) and AI triage had the highest specificity (96.4%). Per 10 000 screened (prevalence, 0.8%), AI reader assistance detected nine more cancers than single human reading (69 vs 60), with 77 additional false-positive recalls (558 vs 481); AI triage had 27% fewer false-positive recalls than single human reading (353 vs 481), with the same cancer detection as double human reading (64 vs 64). Stand-alone AI had the lowest specificity (93.0%) and the most false-positive recalls (<i>n</i> = 694). Rankings are hypothesis-generating: Top-ranked pathways had overlapping credible intervals. Conclusion In this synthesis, AI reader assistance was associated with the highest cancer detection and AI triage with the lowest false-positive recall; stand-alone AI was not supported as a primary screening strategy in settings with existing radiologist capacity. <b>Keywords:</b> Artificial Intelligence, Breast Cancer Screening, Diagnostic Test Accuracy, Deep Learning, Digital Mammography, Mammography, Network Meta-Analysis, Screening Pathway, Computer-aided Diagnosis Systematic review registration no. INPLASY202630080 <i>Supplemental material is available for this article.</i> © RSNA, 2026.