Does access to deep learning uncertainty improve task performance in human readers?
Authors
Affiliations (4)
Affiliations (4)
- Johns Hopkins University, Department of Radiology and Radiological Science, Baltimore, Maryland, United States.
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.
- University of California, Department of Psychological and Brain Sciences, Santa Barbara, California, United States.
- University of Pennsylvania, Department of Radiology, Philadelphia, Pennsylvania, United States.
Abstract
Deep learning image reconstruction or restoration can produce visually high-quality images that may lack familiar visual cues of reliability. Diffusion posterior sampling (DPS) is a stochastic reconstruction algorithm capable of producing samples from the posterior distribution, offering a potential mechanism to communicate uncertainty and a representation of the posterior distribution to radiologists. We designed and conducted an observer study to evaluate whether displaying multiple DPS posterior samples improves task-based performance in human readers compared with displaying a single DPS sample. The observer study evaluated performance for a binary discrimination task involving spiculated and non-spiculated lung lesions. A total of 200 lung lesions were obtained from the Lung Image Database Consortium dataset, including 100 spiculated and 100 non-spiculated lesions. Computed tomography slices containing these lesions were treated as ground truth. Low-dose projection data were simulated and reconstructed using filtered backprojection and DPS. Six radiologists evaluated each case under four display conditions: low-dose filtered backprojection, a single DPS sample, a scrollable stack of 30 DPS samples, and a tiled display of the same 30 DPS samples. Observer performance was assessed using multi-reader multi-case receiver operating characteristic (ROC) analysis, with Lung Image Database Consortium spiculation annotations used as ground truth. Reading time and reader confidence were also recorded. Pooled area under the ROC curves (AUCs) were 0.691 for low-dose filtered-backprojection (FBP), 0.713 for single-sample DPS, 0.750 for the scrollable stack, and 0.747 for the tiled display. Both multi-sample DPS displays improved pooled AUC relative to single-sample DPS at the 10% significance level. The better-performing multi-sample display was reader-dependent. Multi-sample displays were also associated with higher reader confidence than single-sample DPS and FBP displays. Multi-sample displays generally increased reading time, although there was a wide reader-dependent variability in reading time and in which multi-sample display was most time consuming. Averaged over all readers, the scrollable stack and tiled displays increased average reading time by 34.6% and 55.8% relative to low-dose FBP, respectively. Results from the study provide initial evidence that radiologists can use information from multiple posterior samples to improve task-based imaging performance.