Back to all papers

Benchmarking deep learning-based reconstruction methods for photoacoustic computed tomography with clinically relevant synthetic datasets.

October 14, 2026pubmed logopapers

Authors

Chen P,Park S,Jeong G,Cam RM,Villa U,Anastasio MA

Affiliations (4)

  • University of Illinois Urbana-Champaign, Department of Bioengineering, Urbana, Illinois, United States.
  • Washington University in St. Louis, Mallinckrodt Institute of Radiology, St. Louis, Missouri, United States.
  • University of Illinois Urbana-Champaign, Department of Electrical and Computer Engineering, Urbana, Illinois, United States.
  • The University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States.

Abstract

Deep learning (DL)-based image reconstruction methods for photoacoustic computed tomography (PACT) have developed rapidly in recent years. However, most existing methods have not employed standardized datasets, and their evaluations rely on traditional image quality (IQ) metrics that may lack clinical relevance. The absence of a standardized framework for clinically meaningful IQ assessment hinders fair comparison and raises concerns about the reproducibility and reliability of reported advancements in PACT. A benchmarking framework is proposed that provides open-source, anatomically plausible synthetic datasets and evaluation strategies for DL-based acoustic inversion methods in PACT. The datasets each include over 10,000 two-dimensional (2D) stochastic breast objects with clinically relevant lesions and paired measurements at varying modeling complexity. The evaluation strategies incorporate both traditional and task-based IQ measures to assess fidelity and clinical utility. A preliminary benchmarking study is conducted to demonstrate the framework's utility by comparing DL-based and physics-based reconstruction methods. The benchmarking study demonstrated that the proposed framework enabled comprehensive, quantitative comparisons of reconstruction performance and revealed important limitations in certain DL-based methods. Although they performed well according to traditional IQ measures, they often failed to accurately recover lesions. This highlights the inadequacy of traditional metrics and motivates the need for task-based assessments. The proposed benchmarking framework enables systematic comparisons of DL-based acoustic inversion methods for 2D PACT. By integrating clinically relevant synthetic datasets with rigorous evaluation protocols, it enables reproducible, objective assessments and facilitates method development and system optimization in PACT.

Topics

Deep LearningPhotoacoustic TechniquesImage Processing, Computer-AssistedTomography, X-Ray ComputedJournal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.