This study assessed the accuracy of a novel artificial intelligence (AI)-assisted echocardiographic platform for automated measurements in children. In this prospective, blinded, comparative, single-center pilot study, transthoracic echocardiography was performed in pediatric subjects aged 5 to 18 years using the Siemens Acuson Origin cardiovascular ultrasound system. For spectral Doppler assessments, two echocardiographic acquisitions were required: one using the AI-assisted protocol with automatic spectral Doppler marker placement, and one with manual marker placement. For all other analyses, a single manual acquisition was required for subsequent AI and manual assessments. Images were initially analyzed with the AI-assisted protocol, followed immediately by manual evaluation by a pediatric cardiologist blinded to the AI-derived results. Indices included B-mode, M-mode, Doppler, speckle tracking, and four-dimensional (4D) parameters. Agreement between AI-assisted and manual measurements was assessed using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Thirty subjects (23 males; age 12.2±3.8 years) were studied, including 23 with structurally normal heart, six with congenital heart diseases, and one with dilated cardiomyopathy. Feasibility exceeded 90% for 2D AI-assisted assessment and 80% for 4D ventricular volumetry, but was below 35% for 4D atrial volumetry. Agreement between AI-assisted and manual measurements was strong for all parameters except septal (ICC 0.2) and left ventricular posterior wall thickness (ICC 0.5). Bland-Altman analysis showed no significant systematic differences. Our pilot findings suggest that a commercially available AI-assisted echocardiographic system may be feasible and reasonably accurate for conventional and advanced quantitative echocardiographic assessment for children in a real-world setting.

Topics

Artificial IntelligenceEchocardiographyImage Interpretation, Computer-AssistedHeart Defects, CongenitalJournal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.