Back to all papers

A Unified Deep Learning Framework for Motion Correction in Medical Imaging.

November 28, 2026pubmed logopapers

Authors

Wang J,Faghihpirayesh R,Joca D,Golland P,Gholipour A

Affiliations (6)

  • Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.
  • Department of Electrical and Computer Engineering, Northeastern University, Boston, MA 02115, USA.
  • Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
  • Department of Radiological Sciences, University of California Irvine, Irvine, CA 92697, USA.
  • Department of Electrical Engineering and Computer Science, University of California Irvine, Irvine, CA 92697, USA.
  • Department of Biomedical Engineering, University of California Irvine, Irvine, CA 92697, USA.

Abstract

Deep learning has shown significant value in medical image registration for motion correction. However, current techniques are either limited by the type and range of motion they can handle or require iterative inference and/or retraining for new imaging data. To address these limitations, we introduce UniMo, a Unified Motion Correction framework that leverages deep neural networks to correct for various types of motion in medical imaging. UniMo exploits an alternating optimization scheme for a unified loss function to train an integrated model of 1) an equivariant neural network for global rigid motion correction and 2) an encoder-decoder network to correct local deformations. To this end, it features a geometric deformation augmenter that 1) enhances the robustness of global motion correction by addressing any local deformations, whether they are caused by non-rigid motion or geometric distortions, and 2) generates augmented data to improve the training process. UniMo is a hybrid model that uses both image intensities and shapes to achieve robust performance amid image appearance variations; therefore, it generalizes well to various medical imaging modalities without a need for network retraining. We trained and tested UniMo to track motion in fetal magnetic resonance imaging, which is a very challenging application due to 1) the presence of both large rigid and non-rigid motion, and 2) large variations in image appearance. Then we tested the trained model, without retraining, on various image modalities from three public datasets, including MedMNIST, lung CT, and BraTS. The results show that UniMo surpassed existing motion correction methods in terms of accuracy; notably, it enabled one-time training on a single modality while maintaining high stability and adaptability for inference across multiple unseen imaging datasets. By offering a unified solution to motion correction, UniMo marks a significant advantage in challenging applications with a mixture of bulk motion and local deformations. The code is available at: https://github.com/IntelligentImaging/UNIMO.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.