Parsimonious machine learning of preprocedural cardiac CT predicts all-cause mortality after transcatheter aortic valve implantation.
Authors
Affiliations (8)
Affiliations (8)
- Advanced Imaging for Personalized Medicine Unit, Experimental Imaging Center, IRCCS San Raffaele Scientific Institute, Via Olgettina 60, Milan, 20132, Italy.
- School of Medicine, Vita-Salute San Raffaele University, Via Olgettina 58, Milan, 20132, Italy.
- San-Raffaele AI Center (S-RACE), Vita-Salute San Raffaele University, Via Olgettina 58, Milan, 20132, Italy.
- Cardiovascular Imaging Unit, Cardiothoracic Department, IRCCS San Raffaele Scientific Institute, Via Olgettina 60, Milan, 20132, Italy.
- Cardiovascular Imaging Research Center, Minneapolis Heart Institute Foundation, 920 East 28th Street, Suite 100, Minneapolis, MN 55407, United States.
- Allina Health Minneapolis Heart Institute, Abbott Northwestern Hospital, 800 E 28th St, Minneapolis, MN 55407, United States.
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Via Olgettina 60, Milan, 20132, Italy.
- Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, Via Olgettina 60, Milan, 20132, Italy.
Abstract
Prognostication before transcatheter aortic valve implantation (TAVI) remains difficult, with about 10-12% of patients dying within one year. Preprocedural cardiac CT holds largely unexploited prognostic information, but existing machine learning models rely on manual variables, large feature sets, or unexplainable deep learning, and none is publicly deployable. To develop a machine learning (ML) model using preprocedural cardiac CT data for predicting 1-year mortality after TAVI for severe aortic stenosis (AS), deployable as a web-based solution. A retrospective single-center study was conducted on consecutive participants undergoing TAVI from October 2020 to March 2023 (training) and April to November 2023 (internal testing), with CT performed on a dual-source scanner SOMATOM Definition Flash or Drive. Two logistic regression models were developed: full-variable (clinical, echocardiographic, and cardiac CT features) and CT-only (left ventricular ejection fraction and indexed right atrial end-diastolic volume). ROC analysis and risk stratification by tertiles were used for performance evaluation. The CT-only model was further tested with features automatically extracted using TotalSegmentator. The training set included 495 participants (260 [53%] women; median age 82 years [IQR, 78-85]); the internal test set included 143 (72 [50%] women; median age 82 years [IQR, 77-85]). One-year mortality occurred in 56/495 (11%) and 14/143 (10%), respectively. The CT-only model achieved an AUC of 0.67 [95% CI, 0.59-0.75], comparable to the full-variable model (AUC: 0.70 [95% CI, 0.62-0.78]). Internal testing confirmed performance (AUC: 0.68 [95% CI, 0.54-0.81]) and risk stratification into groups of low (1.7%), intermediate (13.5%), and high-risk (17.0%) of 1-year mortality. Automatically extracting CT metrics with TotalSegmentator preserved discrimination (AUC: 0.67 [95% CI, 0.54-0.79]), with outcome probability of 4.3% (low-risk), 11.1% (intermediate-risk), and 14.3% (high-risk). The model was successfully deployed via a web-application (https://uc3-model.srace.ai-hub.it/). An ML model using 2 preprocedural cardiac CT-derived metrics, automatically extractable with open-source tools, predicts 1-year mortality after TAVI. A web-based solution has been made publicly available to facilitate external validation, deployment for prognostication independent of commercial software or multi-source data integration.