Anatomical deformation modes: a compact scalar-mode subspace for patient-specific deformation modeling.
Authors
Affiliations (5)
Affiliations (5)
- UT Southwestern Medical Center, 3301 Hudnall ST, Dallas, Texas, 75390, United States.
- Radiation Oncology, University of Texas Southwestern Medical Center at Dallas, 6363 Forest Park Rd, Dallas, Texas, 75390-9315, United States.
- Radiation Oncology, UT Southwestern Medical Center, 2280 Inwood Road, Dallas, Texas, 75390, United States.
- Department of Radiation Oncology, Stanford University, 875 Blake Wilbur Drive, Stanford, 94305-2004, United States.
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, 2280 Inwood Road, Dallas, Texas, 75235, United States.
Abstract
Objective To develop a patient-specific motion-modeling framework that represents a dense three-dimensional deformation vector field (DVF) as a linear combination of scalar-field bases, termed anatomical deformation modes (ADM), with vector coefficients.

Approach We formulated ADM as a low-dimensional parameterization of the DVF and showed that it generalizes the vector mode (VM) representation at matched spatial-map storage and provides pose invariance. Patient-specific ADM can be either extracted by principal component analysis (PCA) of the component fields of multiple DVFs or predicted from a single CT image by a deep neural network as a population-learned, anatomy-conditioned prior. From sparse 2D or 3D observations, the coefficients, and thus the dense DVF, are recovered by an iterative Gauss-Newton coefficient solver with closed-form linear updates for images and masks, or a single linear least-squares solve for surface points.

Main results On a public 4D-lung CT dataset with pTVReg-derived reference DVFs, ADM achieved a 95th-percentile endpoint error (EPE-P95) of 1.25-1.56 mm versus 1.34-1.62 mm for VM at matched spatial-map storage. A single PCA-derived mode reached EPE-P95 2.48 mm against the reference DVFs on the 3 mm grid, a one-scalar-map budget unavailable to VM. Without retraining, network-predicted ADM supported four CT-derived simulated observation types relevant to real-time guidance (3D images, 2D images, 2D masks and surface points), and one or two modes reduced mean EPE-P95 by 20-31% relative to no registration. Online coefficient fitting required 1.36-3.77 ms for 2D images and masks and 0.044 ms for surface points on an RTX 4090.

Significance Patient-specific deformation models can thus be built from multiple DVFs when prior motion images are available or from a single static CT image before any motion imaging. By encoding patient-specific anatomical and spatial constraints, ADM supports the development of fast, observation-flexible methods for recovering dense deformation from controlled sparse observations.