Biophysical model-based deep learning denoising for stabilized IMPULSED dMRI microenvironment parameter fitting.
Authors
Affiliations (4)
Affiliations (4)
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, 401 North Broadway, Weinberg Bldg, Ste 1440, Baltimore, Maryland, 21218-2625, United States.
- The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd., Houston, Texas, 77030-4000, United States.
- UT Southwestern Department of Radiation Oncology, 2280 Inwood Rd, Dallas, Texas, 75390, United States.
- Department of Radiation Oncology, The University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, Texas, 75390-9303, United States.
Abstract
Diffusion-weighted MRI (dMRI) is a powerful tool for quantifying cellular microenvironment parameters. However, the inherently low signal-to-noise ratio (SNR) of dMRI can compromise the accuracy and reliability of parameter estimation. This study proposes a {\rev biophysical model}-based deep learning (DL) denoising framework designed to enhance dMRI signal quality and improve the robustness of subsequent biophysical model fitting, with potential relevance to low-SNR settings such as clinical 1.5 T MRI acquisitions.

Approach. A dataset of paired noise-free and Rician-noise-corrupted dMRI signals was generated using the IMPULSED-dMRI signal model. Three denoising architectures were evaluated: Convolutional Neural Networks (CNN), Multilayer Perceptron (MLP), and Long Short-Term Memory (LSTM) networks. Denoised signals were then fitted to estimate cell diameter $d$, intracellular volume fraction $V_{\mathrm{in}}$, and extracellular apparent diffusion coefficient $D_\mathrm{ex}$. Performance was assessed using signal-domain Mean Absolute Error (MAE), fitted-parameter MAE, and {\rev boundary solution rate} in synthetic IMPULSED-dMRI data with known ground-truth parameters and in \textit{in vitro} evaluation using HeLa and MC38 cell lines.

Main results. DL-based processing substantially improved dMRI signal denoising. {\rev The MLP and LSTM achieved comparable denoising performance, and both outperformed the CNN.} Averaged across all signals, the LSTM reduced denoising MAE from 5.97\% to 1.58\%. In the subsequent model fitting step, the LSTM produced modest reductions in parameter MAE, from $5.34 \, \mu\text{m}$ to $4.02 \, \mu\text{m}$ for $d$, from 15.00\% to 11.96\% for $V_\mathrm{in}$, and from $0.77$ to $0.63 \, \mu\text{m}^2/\text{ms}$ for $D_\mathrm{ex}$. The dominant benefit was fitting stabilization, with the overall {\rev boundary solution rate} reduced from 57.6\% to 17.7\%. In \textit{in vitro} experiments, relative to experimental references, the LSTM reduced MAE from $2.1 \, \mu\text{m}$ to $0.4 \, \mu\text{m}$ for $d$ and from 7.8 to 5.4 percentage points for $V_\mathrm{in}$, while reducing the mean overall {\rev boundary solution rate} from 17.7\% to 0\%.

Significance.The proposed framework improves dMRI signal quality and stabilizes subsequent IMPULSED-based microenvironmental parameter fitting. The primary value of this approach is improved fitting reliability under noisy dMRI conditions, with secondary gains in parameter accuracy, and it warrants further validation in heterogeneous tissues and \textit{in vivo} datasets.