Back to all papers

MRI-only workflow for preclinical ion beam therapy: Deep-learning-based synthetic CT generation from ultra-high-field small animal MRI.

November 26, 2026pubmed logopapers

Authors

Abdarahmane I,Stocchiero S,Wolf L,Heilemann G,Knäusl B,Zimmermann L,Zeilinger M,Georg D,Kuess P

Affiliations (6)

  • Department of Radiation Oncology, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria; Competence Center for Preclinical Imaging and Biomedical Engineering, Faculty of Health, University of Applied Sciences, Johannes-Gutenberg-Straße 3, A-2700 Wiener Neustadt, Austria; MedAustron Ion Therapy Center, Marie Curie-Straße 5, A-2700 Wiener Neustadt, Austria.
  • Department of Radiation Oncology, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria; MedAustron Ion Therapy Center, Marie Curie-Straße 5, A-2700 Wiener Neustadt, Austria.
  • Department of Radiation Oncology, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria; Christian Doppler Laboratory for Image and Knowledge Driven Precision Radiation Oncology, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria.
  • Department of Radiation Oncology, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria; MedAustron Ion Therapy Center, Marie Curie-Straße 5, A-2700 Wiener Neustadt, Austria; Christian Doppler Laboratory for Image and Knowledge Driven Precision Radiation Oncology, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria.
  • Competence Center for Preclinical Imaging and Biomedical Engineering, Faculty of Health, University of Applied Sciences, Johannes-Gutenberg-Straße 3, A-2700 Wiener Neustadt, Austria; MedAustron Ion Therapy Center, Marie Curie-Straße 5, A-2700 Wiener Neustadt, Austria.
  • Department of Radiation Oncology, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria; MedAustron Ion Therapy Center, Marie Curie-Straße 5, A-2700 Wiener Neustadt, Austria. Electronic address: [email protected].

Abstract

To develop and validate a deep-learning-based magnetic resonance imaging (MRI)-only workflow for preclinical mouse brain irradiations with ion beams and to compare with a rigidly aligned population-averaged CTs (sCTs<sup>avg</sup>). A 3D U-Net was trained on 69 paired ultra-high-field (15.2T) T1-weighted MRIs and micro-CTs (µCTs) from 17 BALB/c mice. Two BALB/c and two C57BL/6 mice were used for independent testing. Two training losses were compared and selected based on cross-validation. Quantitative performance was assessed using mean absolute error (MAE), structural similarity index (SSIM), and bone Dice similarity coefficient (DSC). Treatment plans with X-rays, protons, and carbon ions were analyzed using dose-volume parameters and 3D gamma analysis of the physical dose distribution. For image generation, the intra-strain test set reached an MAE of (138±10)HU and a bone DSC of 0.75-0.80, slightly below the sCT<sup>avg</sup> baseline (0.79-0.80). On the inter-strain test set (C57BL/6), the results were inferior (DSC: 0.59--0.64), while the sCT<sup>avg</sup> retained a DSC of 0.70-0.77. The dose distributions were comparable between plans calculated on the U-Net-based synthetic CT (sCT<sup>UNet</sup>) and on the µCT. The largest deviation occurred in the near-maximum bone dose (D<sub>2%</sub>) with 0.16Gy for both, protons and for carbon ions. This study demonstrated the feasibility of MRI-only treatment planning for preclinical brain irradiation using a U-Net-based sCT generator, reducing the need for dedicated µCT acquisitions. However, limited training data due to ethical constraints challenges cross-cohort generalization, while a rigidly aligned sCT<sup>avg</sup> provided competitive performance but requires an additional registration step.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.