Low-field magnetic resonance imaging of the spine: A systematic review.
Authors
Affiliations (4)
Affiliations (4)
- Radiography and Diagnostic Imaging, School of Medicine, University College Dublin, Ireland; School of Health Sciences (HESAV), University of Applied Sciences and Arts Western Switzerland (HES-SO), Lausanne, 1011, Switzerland; Department of Diagnostic & Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, 1011, Switzerland. Electronic address: [email protected].
- School of Health Sciences (HESAV), University of Applied Sciences and Arts Western Switzerland (HES-SO), Lausanne, 1011, Switzerland. Electronic address: [email protected].
- Department of Diagnostic & Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, 1011, Switzerland. Electronic address: [email protected].
- Department of Diagnostic & Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, 1011, Switzerland. Electronic address: [email protected].
Abstract
High-field magnetic resonance imaging (MRI) remains the clinical reference for spine imaging. Recent developments renewed interest in low-field MRI through improvements in hardware, accessibility, artefact behaviour, and artificial intelligence (AI) based reconstruction. This systematic review summarised the current evidence on low-field MRI for spine imaging. The review followed Joanna Briggs Institute methodology. Six databases, MEDLINE, EMBASE, CINAHL, Web of Science, Scopus, Google Scholar, were searched. Primary human and phantom studies evaluating spine imaging on MRI systems below 1 T were included. Study selection, critical appraisal, and data extraction were performed independently by two reviewers. Due to heterogeneity in outcomes and protocols, only a narrative synthesis was conducted. From 3726 identified records, 14 cross-sectional studies of moderate-good methodological quality were included. Studies evaluated image quality, anatomical evaluation, reader agreement, quantitative measurements, and procedural feasibility. Selected image-quality ratings were lower at 0.55 T than at higher fields. In patients with spinal instrumentation, 0.55 T MRI reduced metal-related artefacts compared with 1.5 T. Upright-capable systems revealed additional findings under loading. Four studies investigated AI-assisted reconstruction, principally assessing image quality or acquisition efficiency. Interpretation was limited by heterogeneous technologies and outcomes, small study samples, limited diagnostic reference standards, and the post hoc spine-specific scope. Low-field MRI provides clinically feasible spine imaging for selected indications and demonstrates specific benefits in metal-related artefact reduction. Current evidence supports its role as a complementary modality rather than a replacement for high-field systems. Larger multicentre studies and rigorous validation of AI-based reconstruction are required. Low-field MRI may complement high-field spine imaging by reducing metal artefacts and revealing load-dependent abnormalities, while AI-based reconstruction remains promising but requires further clinical validation.