Back to all papers

Multicenter Evaluation of a Deep Learning Model for Automatic Contouring of Cardiac Substructures in Adults.

October 12, 2026pubmed logopapers

Authors

Moignier A,Licha A,Felici F,Duverge L,Lange M,Ah-Thiane L,Delpon G,Karlhede A,Löfman F,Skarf F,Söderberg J,Martin-Mervoyer E,Thillays F,Beddok A,Vaugier L

Affiliations (8)

  • Department of Medical Physics, Institut de Cancérologie de l'Ouest, Saint Herblain, France.
  • Department of Radiation Oncology, Institut Godinot, Reims, France.
  • Department of Radiation Oncology, Centre Eugène Marquis, Rennes, France.
  • Department of Radiation Oncology, Institut de Cancérologie de l'Ouest, Saint Herblain, France.
  • Department of Machine Learning, RaySearch Laboratories, Stockholm, Sweden.
  • Department of Cardiology, Institut de Cancérologie de l'Ouest, Saint Herblain, France.
  • Department of Radiation Oncology, Institut Godinot, Reims, France; CRESTIC EA 3804, Université Reims Champagne-Ardenne, Reims, France.
  • Department of Radiation Oncology, Institut de Cancérologie de l'Ouest, Saint Herblain, France; Department of Radiation Oncology, Groupe Hospitalier Bretagne Sud, Lorient, France. Electronic address: [email protected].

Abstract

Efficient delineation of cardiac substructures is essential for assessing radiation-induced cardiac toxicity in thoracic radiotherapy. We clinically evaluated a deep learning model designed for automated segmentation of these structures. The model built in collaboration with XXX (XXX) generated 21 cardiac substructures (whole heart, chambers, coronary arteries, valves, and great vessels). Five radiation oncologists rated raw contours on thirty contrast-enhanced CTs from two institutions using a 4-point Likert scale (3 = no correction, 2 = minor/moderate correction, 1 = major correction, 0 = not performed) and applied corrections when needed. Dice Similarity Coefficients (DSC) and 95th-percentile Hausdorff distances (HD95) were computed to compare model versus reference contours, clinician-corrected versus reference contours, and model versus STAPLE contours. Of 630 structures, 93.8% were scored either 3 or ≥2, and 6.2% received 1 by at least one clinician. For the coronary arteries (210 structures), 88.5% were scored either 3 or ≥ 2. Contour generation took approximately 1 min, with a median review and correction time of 7.0 min per CT (IQR, 5.8-9.8). The median DSC between the model and reference contours was 1.0 across all structures, while it ranged from 0.92 to 1.0 for clinician-corrected versus reference contours. Overall, HD95 was below 5 mm, for both clinicians versus reference and model versus STAPLE. The deep learning model provided satisfactory segmentation of cardiac substructures on contrast-enhanced CT, including coronary arteries. Its integration into a widely adopted treatment planning system lays the foundation for broad clinical implementation.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.