Comparative performance analysis of lung sparse-view reconstruction algorithms for deep learning-based image quality improvement.

November 25, 2026pubmed logopapers

Authors

Adib Y,Driouch M,Youssoufi MA,Drissi LB,Mesradi MR

Affiliations (5)

  • LPHE-Modeling and Simulation, Faculty of Sciences, Mohammed V University in Rabat, Rabat, Morocco. Electronic address: [email protected].
  • LPMS, Faculty of Sciences, Ibn Tofail University in Kenitra, Kenitra, Morocco; Clinique Avicenne, Fes, Morocco.
  • Department of Radiotherapy, National Institute of Oncology, UHC Ibn Sina, Mohammed V University, Rabat, Morocco.
  • LPHE-Modeling and Simulation, Faculty of Sciences, Mohammed V University in Rabat, Rabat, Morocco; College of Physical and Chemical Sciences, Hassan II Academy of Sciences and Technology, Rabat, Morocco.
  • Laboratory of Sciences and Health Technologies, Higher Institute of Health Sciences, Hassan First University in Settat, Settat, Morocco.

Abstract

Sparse-view computed tomography is a promising technique to dramatically reduce the radiation dose delivered to patients; however, it also significantly degrades image quality. We investigated the trade-off between reconstruction algorithms, the number of X-ray projections, and image-quality improvement for 3 reconstruction algorithms. A total of 4586 lung CT images were collected, and the corresponding sparse-view images were simulated and reconstructed using three algorithms, namely the Filtered Back Projection, Simultaneous Iterative Reconstruction Technique, and Conjugate Gradient Least Squares, under six undersampling scenarios: 16, 32, 64, 128, 256, and 512 views. A Cycle-GAN model was developed to generate realistic CT images from low-dose sparse-view CT images. Then, generated images were compared to the ground truth images from a clinical dataset of 25 patients, using the Root Mean Squared Error (RMSE), Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index (SSIM), Universal Image Quality Index (UQI), and Fréchet and Kernel Inception Distances (FID) and (KID). Qualitative evaluation demonstrated good reconstruction of anatomical details across the three algorithms, with difference maps indicating lower reconstruction errors at higher projection counts. Quantitative assessment, however, revealed marked differences among the algorithms, especially in the 16- and 32-view CT sets, where the image improvement task was more challenging, and smaller errors were observed from 64 to 512 views. Furthermore, RMSE, PSNR, and SSIM values indicated higher reconstruction accuracy for FBP and SIRT at higher projection counts, whereas CGLS showed lower accuracy from 128- to 512-view CT. UQI, FID, and KID showed a continuous improvement pattern as the number of projections increased for all algorithms CONCLUSION: Sparse-view CT represents a promising dose-reduction strategy, particularly when combined with deep learning models to preserve higher image quality. CT scans can be performed with fewer X-ray measurements to reduce radiation exposure, but doing so can make images less clear. This study compared several image reconstruction methods and used artificial intelligence to improve low-dose CT images created from fewer X-ray measurements. This study found that image quality improved as the number of measurements increased, and that combining sparse-view CT with artificial intelligence helped preserve important anatomical details despite lower radiation exposure. This matters because these approaches may help reduce radiation dose while maintaining the image quality needed for diagnosis.