AI-enabled Vectorcardiography (AI-VCG) combined with cardiac magnetic resonance for the mechanism of left bundle branch block in patients undergoing cardiac resynchronization therapy.

October 21, 2026pubmed logopapers

Authors

Mihalef V,Passerini T,Sharma P,Bivona DJ,Oomen PJA,Bilchick KC

Affiliations (4)

  • Siemens Healthineers, Princeton, NJ, USA.
  • Department of Medicine, University of Virginia Health System, Charlottesville, VA, USA.
  • Department of Biomedical Engineering, Edwards Lifesciences Foundation Cardiovascular Innovation and Research Center, University of California Irvine, Irvine, CA, USA.
  • Department of Medicine, University of Virginia Health System, Charlottesville, VA, USA. Electronic address: [email protected].

Abstract

Left bundle branch block (LBBB) is a heterogeneous conduction disorder with major implications for cardiac resynchronization therapy (CRT). Conventional ECG criteria incompletely distinguish intact Purkinje activation (IPA-LBBB) from complete conduction block (CCB-LBBB), limiting precision pacing decisions. To develop an AI-based, patient-specific vectorcardiographic (AI-VCG) framework that integrates ECG and cardiac magnetic resonance (CMR) to noninvasively identify LBBB mechanisms. A patient-specific AI-VCG model was constructed using individualized ECG-to-VCG transformations derived from cardiac-torso geometry and expressed in cardiac-centric coordinates. Performance was evaluated using in-silico electrophysiology simulations (n = 48 hearts) and a clinical CRT cohort (n = 38). A physiologically interpretable AI-VCG feature-the integral of the left-right cardiac vector (IcX)-was assessed for mechanism classification. In-silico validation demonstrated strong discrimination of IPA-LBBB versus CCB-LBBB (AUROC 0.96). The clinical IcX analysis separated IPA-LBBB and CCB-LBBB with 100% accuracy in the LBBB subset (n = 25), with a 22.4 μWb gap between the highest IPA and lowest CCB IcX values. Direct comparator analyses showed 100% accuracy for Kors-derived QRS area (but with a narrower gap), 76% accuracy for Strauss criteria, and 68% accuracy for sex-specific QRS duration alone. A patient-specific AI-VCG framework provides an explainable, noninvasive and anatomically grounded representation of LBBB mechanisms. These preliminary results support further validation against conventional ECG and VCG metrics in larger multicenter cohorts.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.