Back to all papers

Deep learning-based post-hoc noise reduction improves quarter-radiation-dose coronary CT angiography.

June 9, 2025pubmed logopapers

Authors

Morikawa T,Nishii T,Tanabe Y,Yoshida K,Toshimori W,Fukuyama N,Toritani H,Suekuni H,Fukuda T,Kido T

Affiliations (3)

  • Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan.
  • Department of Radiology, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan.
  • Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan. Electronic address: [email protected].

Abstract

To evaluate the impact of deep learning-based post-hoc noise reduction (DLNR) on image quality, coronary artery disease reporting and data system (CAD-RADS) assessment, and diagnostic performance in quarter-dose versus full-dose coronary CT angiography (CCTA) on external datasets. We retrospectively reviewed 221 patients who underwent retrospective electrocardiogram-gated CCTA in 2022-2023. Using dose modulation, either mid-diastole or end-systole was scanned at full dose depending on heart rates, and the other phase at quarter dose. Only patients with motion-free coronaries in both phases were included. Images were acquired using iterative reconstruction, and a residual dense network trained on external datasets denoised the quarter-dose images. Image quality was assessed by comparing noise levels using Tukey's test. Two radiologists independently assessed CAD-RADS, with agreement to full-dose images evaluated by Cohen's kappa. Diagnostic performance for significant stenosis referencing full-dose images was compared between quarter-dose and denoised images by the area under the receiver operating characteristic curve (AUC) using the DeLong test. Among 40 cases (age, 71 ± 7 years; 24 males), DLNR reduced noise from 37 to 18 HU (P < 0.001) in quarter-dose CCTA (full-dose images: 22 HU), and improved CAD-RADS agreement from moderate (0.60 [95 % CI: 0.41-0.78]) to excellent (0.82 [95 % CI: 0.66-0.94]). Denoised images demonstrated a superior AUC (0.97 [95 % CI: 0.95-1.00]) for diagnosing significant stenosis compared with original quarter-dose images (0.93 [95 % CI: 0.89-0.98]; P = 0.032). DLNR for quarter-dose CCTA significantly improved image quality, CAD-RADS agreement, and diagnostic performance for detecting significant stenosis referencing full-dose images.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.