Back to all papers

Accuracy and efficiency of artificial intelligence 3-dimensional segmentation and construction of cone-beam computed tomography images for impacted maxillary canines compared with the manual method.

November 24, 2026pubmed logopapers

Authors

Guo C,Kim HJ,Park HS

Affiliations (2)

  • From the Department of Orthodontics, School of Dentistry, Kyungpook National University, Daegu, Korea.
  • From the Department of Orthodontics, School of Dentistry, Kyungpook National University, Daegu, Korea. Electronic address: [email protected].

Abstract

This study aimed to develop and validate an artificial intelligence (AI) framework for the automatic identification, segmentation, and quantitative measurement of impacted maxillary canines. Differences in time and accuracy for segmentation and in the linear and volumetric measurements were compared between AI and manual methods. An AI model based on a mask region-based convolutional neural network (RCNN) with multihead attention (Mask RCNN-MA) was trained using cone-beam computed tomography images from 214 patients with impacted canines. The dataset was divided at the patient level into training (n = 150, 70%), validation (n = 21, 10%), and test (n = 43, 20%) subsets. Segmentation of the maxillary region of interest, canines, and lateral incisors was evaluated using Dice similarity coefficients, sensitivity, specificity, and Hausdorff distance. Linear measurements relative to the occlusal plane and midsagittal plane, volumetric measurements, and canine crown proximity to the lateral incisor root were assessed. AI segmentation required significantly less time than manual segmentation. This model showed good agreement with human reference standards for the metrics including Dice similarity coefficients, sensitivity, specificity, precision, accuracy, and Hausdorff distance. Linear measurements revealed no significant differences between methods, whereas volumetric measurements yielded good agreement with intraclass correlation coefficients above 0.90. The proposed Mask RCNN-MA framework provides an acceptable and reproducible method for cone-beam computed tomography segmentation and for linear, volumetric, and proximity measurements. This AI approach enables standardized 3-dimensional evaluation of impacted canines and may serve as a practical adjunct to orthodontic diagnosis and treatment planning.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.