Back to all papers

Deep learning model for simultaneous vertebral level localization and fracture detection on DXA vertebral fracture assessment images.

September 9, 2026pubmed logopapers

Authors

Cho SW,Moon D,Kim CO,Kim HC,Rhee Y,Hong N

Affiliations (6)

  • Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, South Korea.
  • Yonsei Institute for Digital Health (YIDH), Yonsei University, Seoul, South Korea.
  • Department of Integrative Medicine, Yonsei University College of Medicine, Seoul, South Korea.
  • Department of Preventive Medicine, Yonsei University College of Medicine, Seoul, South Korea.
  • Division of Geriatric Medicine, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, South Korea.
  • Department of Internal Medicine, Institute of Endocrine Research, Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea.

Abstract

While vertebral fracture assessment (VFA) on dual-energy X-ray absorptiometry (DXA) images is widely used to detect osteoporotic vertebral fractures, existing deep learning approaches typically perform either fracture detection or vertebral localization, not both. We developed VERTE-X L, a deep learning model that simultaneously localizes vertebrae (T7-L5) and detects fractures on DXA VFA images, and evaluated its performance in a community-dwelling older adult cohort. We used DXA VFA images from 1000 randomly sampled participants (age ≥65 years) in the Korean Urban Rural Elderly (KURE) cohort, split into training (N = 800) and test (N = 200) sets. VERTE-X L employs a DINOv2-L encoder, a localization decoder for per-vertebra coordinate prediction, and a consistent rank logits (CORAL) ordinal regression module for fracture detection. Performance was evaluated at image and vertebra levels and compared with previously reported detection-only models (VERTE-X and VERTE-X model fine-tuned on VFA data) and localization-only models (VerteNet and Multi-Context Hybrid CNN Transformer). On the held-out test set, VERTE-X L achieved an image-level area under the receiver operating characteristic curve (AUROC) of 0.952 (sensitivity 89.7%, specificity 94.2%, net present value [NPV] 98.2%) and vertebra-level AUROC of 0.957 (NPV 99.7%). Localization success (within 15 pixels) was 94.7% for fracture vertebrae. VERTE-X L outperformed VERTE-X in detection (AUROC 0.952 vs 0.913, P = 0.034) and outperformed VerteNet in localization (mean radial error 10.0 vs. 20.3 px, P < 0.001). The proposed method enables simultaneous fracture detection and vertebral localization on DXA VFA images.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.