Semi-automated Quantitative Assessment of Radiology Resident Reporting Performance Using Large Language Models: A Pilot Study.
Authors
Affiliations (5)
Affiliations (5)
- Université de Lorraine, Inserm, IADI, Nancy, France (G.H., T.Z., M.B., P.G.T.); CHRU-Nancy, Inserm, Université de Lorraine, CIC, Innovation Technologique, Nancy, France (G.H., T.Z.). Electronic address: [email protected].
- CIMRAD, Besançon, France (S.A.).
- Université de Lorraine, Inserm, IADI, Nancy, France (G.H., T.Z., M.B., P.G.T.); CHRU-Nancy, Inserm, Université de Lorraine, CIC, Innovation Technologique, Nancy, France (G.H., T.Z.).
- Université de Lorraine, Inserm, IADI, Nancy, France (G.H., T.Z., M.B., P.G.T.); Neuroradiology Department, CHRU-Nancy, Nancy, France (M.B.).
- Université de Lorraine, Inserm, IADI, Nancy, France (G.H., T.Z., M.B., P.G.T.); Guilloz Imaging Department, CHRU-Nancy, Nancy, France (P.G.T.).
Abstract
To evaluate a semi-automated large language model (LLM)-based scoring pipeline to quantify diagnostic agreement between radiology residents' preliminary and expert-validated final reports. Sixty-eight paired reports from six radiology residents at a single-center were processed through a two-step pipeline: LLM-based data extraction followed by expert validation and LLM scoring. GPT-5 served as the primary model with full intra-rater and inter-rater reproducibility analyses (35 and 68 pairs, respectively); GPT-4 served as the secondary model. Three metrics were computed: Global Obtained Score (GOS), Global Expected Score (GES), and Clinical Similarity Index (CSI). Agreement was assessed using intraclass correlation coefficients (ICC, two-way random, absolute agreement) and Bland-Altman analysis. A discordance review was performed on 22 report pairs with absolute CSI differences >0.10. GPT-5 achieved good-to-excellent intra-rater reproducibility (ICC: GOS 0.91, GES 0.99, CSI 0.88), comparable to expert scoring (0.93, 0.98, 0.82). Agreement between GPT-5 and the expert was good for GOS (ICC 0.88), excellent for GES (0.98), and moderate-to-good for CSI (0.75). CSI agreement improved from ICC 0.52 (GPT-4) to 0.75 (GPT-5), with a 28% reduction in Bland-Altman limits of agreement. Inter-human agreement on a discordant-enriched subset was moderate to good (ICC: GOS 0.83, GES 0.85, CSI 0.71). Discordance analysis identified five recurring error categories and one hallucination. In 7/30 (23.3%) reviewed disagreements, the expert retrospectively agreed with GPT-5 scoring, including clinically impactful discrepancies initially overlooked during expert scoring. The proposed framework provides a structured and reproducible approach for quantitative assessment of radiology resident reporting performance. These preliminary findings support feasibility and warrant larger multicenter validation before educational deployment.