Neural networks improve repeatability of intravoxel incoherent motion (IVIM) parameter estimation in pancreatic diffusion-weighted MRI.

July 29, 2026pubmed logopapers

Authors

Avidan-Pearl N,Link-Sourani D,Weiss R,Freiman M

Affiliations (4)

  • Faculty of Biomedical Engineering, Technion Israel Institute of Technology, Haifa, 3200003, Israel. [email protected].
  • Faculty of Biomedical Engineering, Technion Israel Institute of Technology, Haifa, 3200003, Israel.
  • The May-Blum-Dahl MRI Research Center, Faculty of Biomedical Engineering, Technion Israel Institute of Technology, Street, Haifa, 3200003, Israel.
  • Department of Pediatrics, Ruth Children's Hospital, Rambam Medical Center, Haifa, Israel.

Abstract

Intravoxel incoherent motion (IVIM) analysis in diffusion-weighted MRI (DWI-MRI) shows potential for characterizing pancreatic tissue, but its clinical application remains limited by sensitivity to fitting algorithms. This study assessed the repeatability of neural network (NN)-based IVIM fitting versus classical nonlinear least-squares in pancreatic DWI. The repeatability cohort included ten healthy volunteers and two type 1 diabetes (T1D) individuals, each scanned twice; the glucose-response cohort included three T1D participants and three healthy controls scanned pre- and post-oral glucose. Diffusion data were acquired at 13 b-values (0-1200 s/mm[Formula: see text]). Four NN-based methods (IVIM-NET, SUPER-IVIM-DC, U-Net, IVIM-MORPH) were compared with two classical approaches (SLS, SLS-TRF) using full (13-point) and reduced (7-point) protocols. Repeatability was quantified using within-subject coefficient of variation (wCV) and Bland-Altman analysis. All NN-based methods significantly improved test-retest repeatability of the perfusion fraction ƒ compared with classical approaches ([Formula: see text]), with SUPER-IVIM-DC showing the lowest wCV and IVIM-MORPH offering balanced performance across parameters. A reduced protocol shortened scan time through fewer acquisitions while maintaining or improving repeatability compared to the full protocol. Preliminary glucose-response results show both NN and classical IVIM analyses detect physiologically relevant changes. Parameter estimates varied across NN architectures, requiring further validation to establish accuracy.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.