Native-Resolution Cascaded Refinement Improves Reliability of Automated Landmark Localization on Full-Length Lower-Limb Radiographs.

November 24, 2026pubmed logopapers

Authors

Zhu J,Han J,Xiao Y,Li M,Zhang R,Dong J,Zhao Z,Wang J,Lu W,Lei J,Zhu W,Huang X,Hua Z

Affiliations (5)

  • School of Mechatronic Engineering and Automation, Shanghai University, 333 Nanchen Rd., Shanghai, 200444, China. [email protected].
  • School of Mechatronic Engineering and Automation, Shanghai University, 333 Nanchen Rd., Shanghai, 200444, China.
  • Third Hospital of Hebei Medical University, Shijiazhuang, 050000, China.
  • Longhua Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, 200032, China.
  • The First Affiliated Hospital of Shenzhen University, Shenzhen, 518060, China.

Abstract

To assess whether native-resolution cascaded refinement improves the reliability of automated lower-limb landmark localization beyond mean error. This retrospective study included 965 full-length lower-limb radiographs from distinct Osteoarthritis Initiative participants (675 training, 144 validation, 146 internal evaluation). Sixteen landmarks were localized by 512 × 512 heatmap regression and refined within 256 × 256 native-resolution regions. Analyses covered landmark-specific errors, alignment measurements, cross-dataset and prosthesis stress tests, image perturbations, and failure recognition using 12 inference-only features. Paired bootstrap intervals retained within-radiograph clustering. Evaluation used reference-informed image preparation and documented image-coordinate scales. Refinement reduced mean radial error from 2.433 to 1.987 image-grid mm. Cases with mean error greater than 3 mm decreased from 13.0% (19/146) to 3.4% (5/146), and landmarks within 3 mm increased from 71.5% (1671/2336) to 80.4% (1877/2336). Lateral femoral condyles accounted for 40/106 residual landmark errors above 5 mm. Mean absolute mechanical lateral distal femoral and medial proximal tibial angle errors decreased by 0.620° and 0.276°, respectively; change intervals for hip-knee-ankle angle and mechanical axis deviation included zero. The risk model improved failure ranking during validation but did not outperform ensemble disagreement on internal evaluation. Native-resolution cascaded refinement improved tail reliability, with measurement benefits concentrated in joint-orientation angles. Inference-time features did not provide a generalizable failure-warning mechanism.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.