Back to all papers

Evaluation Design and Reported Accuracy of Deep Learning Mandibular Canal Segmentation: A Systematic Review and Meta-Analysis.

November 23, 2026pubmed logopapers

Authors

Yıldırım EB,Dalbah I

Affiliations (2)

  • Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Gazi University, Ankara, Turkey.
  • Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Gazi University, Ankara, Turkey. [email protected].

Abstract

Reported accuracy of deep learning mandibular canal segmentation varies widely, and studies differ in how it was evaluated. This systematic review estimated accuracy under explicit validity criteria and described how it varied with evaluation design. Five databases were searched to May 2026 (PROSPERO CRD420261403406). Dice similarity coefficients (DSCs) from three-dimensional, patient-level-partitioned cone-beam computed tomography (CBCT) or CT test sets were pooled by random-effects meta-analysis on the logit scale. Public benchmark results were analyzed separately, and test sets whose reference was generated by the evaluated model were not pooled. Fifty-four studies were included. Pooled DSC across 15 studies was 0.826 (95% confidence interval 0.752-0.881; 95% prediction interval 0.444-0.966), close to three previous reviews with different inclusion rules (0.80-0.84). The 16 CBCT studies ineligible for pooling, mostly for two-dimensional slice-level segmentation or fewer than 10 test patients, reported a higher median DSC (0.860 versus 0.803). Two systems on the official ToothFairy test set had a pooled DSC of 0.751. Internal and external estimates did not differ significantly (P =  .974), but five external studies cannot establish equivalence. Pooled 95th-percentile Hausdorff distance across seven studies was 1.15 mm, with a prediction interval extending to 6.11 mm. Risk of bias was unclear or high in 14 of 15 pooled studies, and certainty of evidence was very low. Average accuracy is consistent across reviews, higher median values came, descriptively, from less constrained evaluations, and external evidence is too limited to show that performance transfers to new settings. Expert verification and prospective external validation remain necessary.

Topics

Journal ArticleReview

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.