Back to all papers

AI-Assisted Multimodal Imaging Integration for Individualized Transseptal Puncture Planning During Atrial Fibrillation Ablation.

November 23, 2026pubmed logopapers

Authors

Liu Z,Wang J,Wang W,Sun Y,Zhou J,Liu Y,Cao M,Wang S,Zou C

Affiliations (2)

  • Department of Cardiology, First Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China.
  • Department of Cardiology, First Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China. [email protected].

Abstract

Transseptal puncture (TSP) is a critical step during atrial fibrillation (AF) ablation, and accurate anatomical understanding of the interatrial septum is essential for individualized procedural planning. Intracardiac echocardiography (ICE) provides real-time visualization of septal anatomy but is limited by its two-dimensional representation and operator dependence. This study developed an artificial intelligence (AI)-assisted multimodal imaging framework integrating preprocedural computed tomography angiography (CTA) with intraoperative ICE to provide patient-specific three-dimensional (3D) anatomical guidance for TSP planning. This single-center study enrolled 700 patients undergoing AF ablation. An AI framework was developed using data from 500 patients to perform automated segmentation, 3D reconstruction, and CTA-ICE multimodal image integration. The framework was evaluated in an independent temporal validation cohort of 200 patients. The primary outcome was the influence of AI-assisted anatomical information on individualized TSP planning, assessed by changes in puncture strategy following AI-assisted assessment. Secondary outcomes included decision confidence, planning time, interreader agreement, and procedural feasibility. The AI framework achieved an overall Dice similarity coefficient of 0.854 for automated anatomical segmentation and a Dice coefficient of 0.862 for 3D left atrial reconstruction. In the temporal validation cohort, at least one AI-recommended adjustment was incorporated into the final TSP strategy in 68 patients (34.0%). The recommendations addressed involved three key components of TSP planning: puncture site category in 52 patients (26.0%), puncture direction in 61 patients (30.5%), and puncture trajectory or angle in 74 patients (37.0%). AI-assisted assessment increased decision confidence (4.3 ± 0.6 vs. 3.4 ± 0.8, p < 0.001), reduced planning time (28.7 ± 10.3 vs. 42.5 ± 15.2 s, p < 0.001), and improved interreader agreement for anatomical assessment. In the temporal validation cohort, acute successful TSP was achieved in 196 patients (98.0%), with a mean transseptal time of 6.8-2.5 min and an overall complication rate of 3.0%. AI-assisted integration of preprocedural CTA with intraoperative ICE provides patient-specific 3D anatomical information that supports individualized TSP planning. The proposed framework demonstrated feasibility and compatibility with anatomical assessment and procedural planning, hopefully contributing to improve procedural or clinical outcomes.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.