Diagnostic Performance and Concordance of a BI-RADS-Output AI System in Mammography: A Retrospective Study of Radiologists-AI Collaboration.

October 23, 2026pubmed logopapers

Authors

Gong X,Zhang L,Kong J,Mou F

Affiliations (3)

  • Department of Radiology, Chongqing University Three Gorges Hospital, Chongqing, China. [email protected].
  • Department of Radiology, Chongqing University Three Gorges Hospital, Chongqing, China.
  • Department of Radiology, Chongqing University Three Gorges Hospital, Chongqing, China. [email protected].

Abstract

The identification of breast cancer using mammography and ultrasonography is influenced by inter-observer variability. Artificial intelligence (AI) models for breast classification have been investigated, but limited reports exist on Breast Imaging Reporting and Data System (BI-RADS)-output AI systems. This study attempted to assess a BI-RADS-output AI system by comparing breast cancer detection rates among radiologist-only, AI-only, and combined interpretations, while also focusing on the AI's ability to identify cancers missed by radiologists and analyzing diagnostic concordance concerning imaging features and BI-RADS categories. A retrospective analysis was performed on 331 lesions from 321 consecutive breast cancer patients who underwent preoperative digital mammography and ultrasonography. McNemar's test was used to find the detection rates, and chi-square/Fisher's test, Receiver Operating Characteristic Curve (ROC) analysis, and Kappa statistics were used to verify the diagnostic performance. The combined radiologist-AI interpretation achieved the highest cancer detection rate of 90.6%, which was higher than the radiologist's rate of 87.6% and the AI's rate of 84.0% (P < 0.05). The advantage was especially evident for BI-RADS 4B lesions, where AI alone decreased to 54.4%, while the combined method increased to 81.8%. AI found tumors that radiologists missed, with an area under the receiver operating characteristic curve (AUC) of 0.840. There was a strong agreement for microcalcifications (κ = 0.827), but only a weak to moderate agreement for mass morphology and final BI-RADS classification (κ = 0.142-0.414). Although AI-radiologist agreement varied across different imaging features, their complementary strengths enabled improved cancer detection performance, supporting the role of BI-RADS-output AI systems as clinical decision-support tools rather than replacements for radiologists.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.