Back to all papers

Planning CT-Guided Dual-Branch Attention GAN for Longitudinal CBCT Outpainting in Adaptive Radiotherapy.

August 11, 2026pubmed logopapers

Authors

Chung S,Kim JH,Chung MG,Jin H

Affiliations (10)

  • Department of Software Convergence, Seoul Women's University, 621 Hwarang-ro, Nowon-gu, Seoul, 01797, Republic of Korea.
  • Department of Radiation Oncology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.
  • Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, 03080, Republic of Korea.
  • Biomedical Research Institute, Seoul National University Hospital, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Republic of Korea.
  • Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, 03080, Republic of Korea.
  • Department of Software Convergence, Seoul Women's University, 621 Hwarang-ro, Nowon-gu, Seoul, 01797, Republic of Korea. [email protected].
  • Project Group of the Gijang Heavy Ion Medical Accelerator, Seoul National University Hospital, Seoul, 03080, Republic of Korea. [email protected].
  • Department of Radiation Oncology, Seoul National University Hospital, Seoul, 03080, Republic of Korea. [email protected].
  • Biomedical Research Institute, Seoul National University Hospital, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Republic of Korea. [email protected].
  • Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, 03080, Republic of Korea. [email protected].

Abstract

Limited longitudinal field of view in cone-beam computed tomography (CBCT) remains a significant challenge for image-guided adaptive radiotherapy. We developed a deep learning-based CBCT outpainting framework that synthesizes anatomically consistent extensions beyond the scanned volume. The model employs a dual-branch encoder-decoder architecture that separately encodes CBCT and edge maps derived from planning CT (pCT) and integrates them via attention-guided skip connections and late fusion to preserve structure while accommodating cross-modality differences. The framework was trained and validated using 90 prostate cancer cases, with 20 held-out patients used for quantitative evaluation against four baseline models. The proposed method achieved the lowest absolute volume difference for the clinical target volume at 0.11 ± 0.07 cc and for the planning target volume at 0.05 ± 0.04 cc. It also yielded superior perceptual image quality, with LPIPS of 0.119 ± 0.029 and FID of 54.70. Qualitative assessment confirmed improved soft-tissue continuity and more faithful preservation of anatomical landmarks in both bony and low-contrast regions. These results demonstrate that the proposed framework can restore CBCT longitudinal coverage with high anatomical fidelity, supporting more reliable deformable registration and adaptive radiotherapy workflows in clinical environments constrained by limited-FOV CBCT.