Development and external validation of an AI pipeline for automated estimation of a radiographic DMFT (rDMFT) score from panoramic radiographs: a feasibility study.
Authors
Affiliations (4)
Affiliations (4)
- Department of Oral, Maxillofacial and Facial Plastic Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, 40225, Germany. [email protected].
- Department of Oral and Maxillofacial Surgery, University Clinic Ruppin-Brandenburg, Neuruppin, 16816, Germany.
- Department of Oral, Maxillofacial and Facial Plastic Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, 40225, Germany.
- Department of Oral and Maxillofacial Plastic Surgery, University Hospital of Würzburg, Würzburg, 97070, Germany.
Abstract
To assess the feasibility of estimating a radiographic Decayed-Missing-Filled-Teeth score (rDMFT), a proxy for the clinical DMFT index, from a single panoramic radiograph with a position-aware deep-learning pipeline. A tooth-status detector and a tooth-numbering detector (32 FDI positions), trained on DENTEX 2023, were combined in a position-aware read-out (one tooth per FDI position, third molars excluded, missing teeth = 28 - occupied positions) and validated on 100 panoramic radiographs from an independent hospital against a two-dentist, radiograph-based reference (intraclass correlation coefficient, ICC; mean absolute error, MAE; Bland-Altman analysis). Against the reference, the pipeline reached an ICC of 0.84 (95% CI 0.74 to 0.90) and an MAE of 2.38, below the between-dentist agreement in point estimate (ICC 0.88, MAE 2.13), with larger errors against each dentist alone (MAE 3.00 and 2.73) and a bias of + 1.14 units from caries over-detection; agreement was highest for filled (r 0.90) and lowest for decayed teeth (r 0.34; dentists 0.16). In the 26 radiographs with missing teeth the missing count was exact in 42% (62% within ± 1 tooth), and missing teeth were over-called in 15 of 74 complete dentitions; tooth loss was no longer overlooked (26 of 26 detected), but the overall ICC was 0.84 versus 0.90 without numbering. Automated rDMFT estimation is feasible, but agreement was lower in point estimate than between two dentists, with larger errors against each dentist. The missing component now responds to actual tooth loss but remains imprecise and is over-called in some complete dentitions; the decayed component is unreliable. The pipeline is a research building block, not a decision-support or triage tool. rDMFT is a radiographic proxy, not a clinical measure, and the pipeline is not proposed for clinical use; any application would first require validation in unselected cohorts against clinically determined reference standards.