Back to all papers

Threshold optimization of artificial intelligence in digital breast tomosynthesis screening: a retrospective comparison study.

November 27, 2026pubmed logopapers

Authors

Yang LC,Cheng TY,Chen KI,Tsai MY,Wang WT,Chou CP

Affiliations (7)

  • Department of Radiology, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan.
  • College of Nursing, Kaohsiung Medical University, Kaohsiung, Taiwan.
  • Department of Nursing, Fooyin University, Kaohsiung, Taiwan.
  • Department of Medical Imaging and Radiology, Shu-Zen Junior College of Medicine and Management, Kaohsiung, Taiwan.
  • School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
  • Department of Radiology, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan. [email protected].
  • Department of Medical Laboratory Science and Biotechnology, Fooyin University, Kaohsiung, Taiwan. [email protected].

Abstract

To evaluate the diagnostic performance of a deep learning-based artificial intelligence (AI) system for digital breast tomosynthesis (DBT) screening and to compare its performance with radiologist-plus-CAD interpretation across multiple operating thresholds. This retrospective study included 1780 asymptomatic women who underwent screening DBT between July 2021 and June 2022. Radiologists interpreted examinations using BI-RADS, 5th edition; the AI system independently analyzed the examinations. Three operating thresholds were assessed: high-sensitivity threshold (HST) (≥ 2%), Youden index threshold (YIT) (≥ 27%), and recall rate-matched threshold (RMT) (≥ 36%). The reference standard was histopathologic confirmation for positive cases and a 24-month follow-up for negative cases. Sensitivity, specificity, and recall rates were compared using the McNemar test. Among 1780 women (mean age ± SD, 55.7 ± 7.4 years), 1469 (82.5%) had dense breasts (BI-RADS density category C or D). Eighteen cancers were confirmed: 12 screen-detected and 6 interval cancers (cancer rate in the cohort, 10.1 per 1000 examinations). At the YIT (≥ 27%), AI achieved numerically higher sensitivity than radiologist-plus-CAD (77.8% (14/18) vs 66.7% (12/18)), although this difference was not statistically significant (p = 0.457), with lower specificity (81.2% vs 95.2%; p < 0.001) and a higher recall rate (19.4% vs 5.4%; p < 0.001). Negative predictive value (NPV) was high for both (99.7% vs 99.6%). AI detected two of six interval cancers missed by radiologist-plus-CAD; four interval cancers were missed by both methods. Standalone AI performance was threshold-dependent, with numerically higher sensitivity but significantly lower specificity than radiologist-plus-CAD, requiring external validation given the limited sample. Question What is the optimal threshold for standalone artificial intelligence in digital breast tomosynthesis screening to balance cancer detection and recall rates? Findings Standalone artificial intelligence showed numerically higher sensitivity but significantly lower specificity than radiologist-plus-CAD (81.2% vs 95.2%), with threshold choice shaping detection and recall. Clinical relevance In digital breast tomosynthesis screening, standalone AI performance varied with the selected threshold. At the Youden threshold, AI maintained a high negative predictive value and detected 2 of 6 interval cancers; the small cancer sample limits conclusions about clinical benefit.