Independent evaluation of eight deep learning breast cancer detection algorithms as a second reader and for triage in a UK breast screening cohort.

November 25, 2026pubmed logopapers

Authors

Rothwell J,Hickman SE,Payne NR,Kaggie JD,Black RT,Huang Y,Nanaa M,Kilburn-Toppin F,Gilbert FJ

Affiliations (5)

  • Department of Radiology, University of Cambridge School of Clinical Medicine, Cambridge, UK.
  • Department of Radiology, Barts Health NHS Trust, The Royal London Hospital, London, UK.
  • EPSRC Cambridge Mathematics of Information in Healthcare Hub, University of Cambridge, Cambridge, UK.
  • Department of Radiology, Royal Bolton Hospital, Bolton, UK.
  • Department of Radiology, University of Cambridge School of Clinical Medicine, Cambridge, UK. [email protected].

Abstract

To benchmark commercial breast cancer detection algorithms for standalone reading, paired reading, and triage in a UK cohort. Digital mammograms were retrospectively collected from two UK Breast Screening Programme sites (Cambridge and Norwich; 2017), excluding mammograms without two-view images, 3-year follow-up, or algorithm scores. Eight algorithms from five companies were assessed at single-reader specificity as a standalone reader or paired with the first human reader, and in low- and high-suspicion triage scenarios. The reference standard was histopathologically confirmed cancer (screen-detected, interval, or next-round). Performance metrics included AUC, sensitivity, specificity, recall rate, and arbitration rate; noninferiority was assessed at a 5% margin. Of 22,778 mammograms (median age: 59 years; IQR: 54-63), 294 were screen-detected, 151 were interval, and 209 were next-round cancers. AUCs ranged 0.82-0.91; one algorithm was inferior to all others (p < 0.001). As a standalone reader, four algorithms had noninferior sensitivity (range: 47.2-64.5%) versus single reading (62.9%). Paired with the first reader, sensitivities were 64.7-67.4% (all but one noninferior to double reading: 67.9%) and specificities 97.5% (all superior to double reading: 97.1%; all p < 0.001). Low-suspicion triage ruled out 37.4-65.7% of mammograms, missing ≤ 1.0% of screen-detected cancers; high-suspicion triage ruled in 3.6-12.2% of interval and next-round cancers. In combined triage, sensitivity (68.8-71.2%) was superior to double reading for five algorithms and noninferior for the remainder. Algorithms demonstrated variable standalone performance. When paired with a human reader, all but one were noninferior to double reading; in a combined triage workflow, all were noninferior and several had superior sensitivity. Question How do eight commercial deep learning algorithms from five vendors compare as standalone readers, paired with a single reader, and for triage in a UK breast screening cohort? Findings Most algorithms performed comparably and were noninferior in sensitivity to double reading when paired with a single reader, with one consistent underperformer; combined triage was noninferior or superior in sensitivity while maintaining specificity, at the cost of increased arbitration. Clinical relevance Commercial algorithms differ in performance, and newer versions are not necessarily better, supporting independent, head-to-head evaluation before prospective evaluation.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.