Back to all papers

Use of a large language model for identification and extraction of actionable details from recommendations for additional imaging in abdominopelvic CT reports.

November 24, 2026pubmed logopapers

Authors

Frank RA,Carney A,Mojtahed A,Khorasani R,Burk KS,Lacson R

Affiliations (5)

  • Brigham and Women's Hospital, Boston, USA.
  • Harvard Medical School, Harvard University, Boston, USA.
  • Massachusetts General Hospital, Boston, USA.
  • Brigham and Women's Hospital, Boston, USA. [email protected].
  • Harvard Medical School, Harvard University, Boston, USA. [email protected].

Abstract

Automated identification and extraction of recommendations for additional imaging (RAI) from radiology reports could facilitate closed-loop tracking and follow-up completion. We compare a prompt-engineered GPT-4.1 large language model (LLM) versus a validated encoder-only transformer deep learning model (bidirectional encoder representations from transformers [BERT]) for detection of RAI in abdominopelvic computed tomography (CTAP) reports, and evaluate GPT-4.1 for extraction of actionable RAI elements. This retrospective study included CTAP reports from a multi-institution system in 2023. LLM and BERT were used to identify RAI from radiology reports; LLM also extracted RAI actionable elements (modality, body part, time frame, rationale). Recall, precision, F1, and accuracy for RAI detection were determined using human-annotated reference standard. Paired comparison between each model's accuracy used McNemar's test. LLM recall, precision, F1, and accuracy for actionable element extraction were computed. Element prevalence was compared using chi-square test. 2000 random reports for unique patients (58% women; mean age 58.5 ± 17.5) included 215 RAI within 206 reports. For RAI detection, GPT-4.1 recall, precision, F1 and accuracy were 95.6%, 98.5%, 97.0% and 99.4%, respectively; BERT recall, precision, F1 and accuracy were 93.7%, 96.5%, 95.1% and 99.0% (p = 0.16). Recommendation element recall were as follows: 100.0% for time frame, 93.9% for body part, 90.2% for rationale, and 94.2% for modality. Precision were 100.0%, 95.7%, 94.6% and 86.1%, respectively. 29/215 (13.5%) RAI were complete (specified all actionable elements). Prevalence of actionable elements varied (p < 0.001), highest for rationale (215/215, 100%), followed by body part (213/215, 99.1%), modality (191/215, 88.8%), and time frame (31/215, 14.4%). GPT-4.1 demonstrated high accuracy for extraction of RAI and enabled accurate extraction of actionable elements. LLM integration into radiology workflows can facilitate automatic closed-loop communication and tracking of recommended imaging, which may reduce diagnostic delays.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.