Back to all papers

Application of large language models for assigning clear cell likelihood score v2.0 from free-text MRI reports: a feasibility study.

October 5, 2026pubmed logopapers

Authors

Duan Y,Zhao Y,He M,Li T,Yang L,Hu Z,Wang M,Feng Z

Affiliations (6)

  • Department of Radiology, Beilun Branch of the First Affiliated Hospital, College of Medicine, Zhejiang University, Ningbo, Zhejiang, China.
  • Department of Radiology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China.
  • Department of General Surgery, Beilun Branch of the First Affiliated Hospital, College of Medicine, Zhejiang University, Ningbo, Zhejiang, China.
  • Department of Radiology, Yuhang District Second People's Hospital, Hangzhou, Zhejiang, China.
  • Department of Radiology, The First Affiliated Hospital of Wannan Medical University (Yijishan Hospital of Wannan Medical University), Wuhu, Anhui, China.
  • Department of Radiology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China. [email protected].

Abstract

To evaluate the performance of four large language models (LLMs) for automated feature extraction and clear cell likelihood score version 2.0 (ccLS v2.0) assignment from free-text reports using a multi-step prompting strategy. This retrospective multicenter study included 1,048 magnetic resonance imaging (MRI) reports of renal masses from three institutions (2020-2026). Four LLMs (DeepSeek-V3.2, Qwen 3.5, GPT-5.3, and Gemini 3.0) were evaluated for automated ccLS v2.0 assignment through a three-stage prompting workflow: (1) feature extraction, (2) rule-based criteria matching, and (3) final categorization. Performance was evaluated against expert radiologist consensus-based ccLS v2.0 assignments. Accordingly, these results primarily reflect agreement in task execution rather than diagnostic accuracy for ccRCC. Gemini 3.0 achieved the highest overall accuracy, correctly assigning ccLS categories in 683 of 802 reports in the internal cohort (85.2%; 95% CI, 82.5%-87.5%) and 211 of 246 reports in the external validation cohort (85.8%; 95% CI, 80.9%-89.6%). All LLMs achieved accuracy greater than 80% for assigning high-risk categories (ccLS 4-5). Gemini 3.0 showed comparatively strong performance in extracting individual imaging features, such as T2-weighted imaging (T2WI) hyperintensity. However, all models showed reduced performance for features requiring multi-step interpretation, particularly the arterial-to-delayed enhancement ratio (ADR), with Qwen 3.5 showing the weakest performance for these complex features. In the pathology subgroup of the internal cohort (n = 237), expert report-based scores yielded an AUC of 0.799 for identifying ccRCC, with LLM-assigned scores showing AUCs of 0.768-0.791 and small AUC differences from the expert standard (-0.031 to -0.008) with overlapping 95% CIs. LLMs employing multi-step prompting, particularly Gemini 3.0, demonstrated favorable performance in assigning ccLS v2.0 categories from free-text reports. Despite limitations in complex feature reasoning, these models showed potential for supporting automated ccLS assessment in radiology workflows; however, in their current implementation, they should be considered decision-support tools that require expert verification rather than autonomous, unsupervised scoring.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.