Back to all papers

Performance of a self-supervised pretrained neural network for orthopedic radiograph classification.

November 23, 2026pubmed logopapers

Authors

Bagchi R,Yee NJ,Kwon JY,Taseh A,Ashkani-Esfahani S

Affiliations (6)

  • Foot & Ankle Research and Innovation Lab (FARIL), Department of Orthopedic Surgery, Mass General Brigham, Harvard Medical School, Boston, MA, USA. [email protected].
  • Case Western Reserve University School of Medicine, Cleveland, OH, USA. [email protected].
  • Foot & Ankle Research and Innovation Lab (FARIL), Department of Orthopedic Surgery, Mass General Brigham, Harvard Medical School, Boston, MA, USA.
  • Division of Orthopedic Surgery, Department of Surgery, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada.
  • Institute of Biomedical Engineering, Faculty of Applied Science and Engineering, University of Toronto, Toronto, ON, Canada.
  • Division of Foot and Ankle, Department of Orthopedic Surgery, Mass General Brigham, Harvard Medical School, Boston, MA, USA.

Abstract

To evaluate whether domain-adaptive self-supervised pretraining of a convolutional neural network on musculoskeletal radiographs improves binary fracture classification and attribution faithfulness relative to ImageNet-pretrained baselines. This retrospective study (conducted June 2025 to May 2026) compared three initializations of a ResNet-50 convolutional neural network: supervised ImageNet (control), self-supervised ImageNet (DINO), and DINO further pretrained on 44,029 musculoskeletal radiographs (DINO-Ortho). Each was fine-tuned in three experiments: in-distribution (MURA and FracAtlas), out-of-distribution (5365 external calcaneal radiographs from 1775 patients acquired during 2015-2022), and initial weights (calcaneal fine-tuning). Attribution faithfulness was quantified using Remove and Debias (ROAD) scores from Grad-CAM saliency maps, with higher scores indicating greater faithfulness. AUROCs were compared using DeLong tests, and ROAD scores using Friedman tests with Bonferroni-adjusted post hoc pairwise comparisons. DINO-Ortho AUROC did not differ significantly from either baseline in any experiment (0.82 [95% confidence interval, 0.79-0.84] in-distribution and 0.95 [0.93-0.96] with initial weights). DINO-Ortho ROAD scores were significantly higher than both baselines in-distribution (20.01 vs 3.70 and 9.35, respectively) and with initial weights (20.41 vs 12.15 and 1.67, respectively, P < 0.001 for all) and higher than control but not DINO out-of-distribution (15.47 vs 3.06 and 16.09, respectively). All models discriminated poorly out-of-distribution (AUROC 0.65 [0.63-0.67], 0.64 [0.63-0.66], and 0.64 [0.63-0.66] for control, DINO, and DINO-Ortho, respectively). With no significant difference in AUROC from either baseline, domain-adapted self-supervised pretraining yielded more faithful attributions than supervised ImageNet pretraining in every experiment and than self-supervised ImageNet pretraining in two of three. No model generalized adequately to unfamiliar anatomy without fine-tuning. Groups fine-tuning on their own musculoskeletal data should therefore consider domain-adapted weights, whose saliency maps more reliably show what drove each prediction, making reliance on irrelevant features easier to detect.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.