Diagnostic accuracy and clinical utility of AI-based chest radiograph assessment for osteoporosis: an updated systematic review and meta-analysis.
Authors
Affiliations (6)
Affiliations (6)
- Department of Medical Course, Faculty of Health and Medical Science, Teikyo Heisei University, Tokyo, Japan. [email protected].
- Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan. [email protected].
- Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan.
- Department of Orthopedic Surgery, Hashimoto Hospital, Kagawa, Japan.
- Division of Physical Therapy, Department of Rehabilitation, Faculty of Health Sciences, Nagano University of Health and Medicine, Nagano, Japan.
- Department of Orthopaedic Surgery, Akita University Graduate School of Medicine, Akita, Japan.
Abstract
Opportunistic screening using artificial intelligence (AI) on routine chest radiographs has emerged as a promising approach for identifying individuals at high risk for osteoporosis. However, prior reviews have not fully evaluated generalizability using dedicated external validation cohorts or formally assessed clinical utility. We conducted an updated systematic review and meta-analysis to address these gaps. We systematically searched CENTRAL, MEDLINE, EMBASE, and IEEE Xplore through February 24, 2026. We included studies evaluating the diagnostic accuracy of AI-based chest radiograph assessment for osteoporosis using DXA as the reference standard. We used bivariate random-effects models to pool sensitivity and specificity. We assessed study quality using QUADAS-AI and APPRAISE-AI. We performed post hoc exploratory analyses using classification-based expected-to-observed (E/O) ratios and a net-benefit approximation derived from study-level contingency tables; these analyses were not prespecified in the registered protocol. Twenty-seven studies (95,106 participants, 111,486 images) were included, with 20 in the meta-analysis. In external validation studies (n = 7), pooled sensitivity was 0.86 (95% CI: 0.71-0.94), pooled specificity was 0.73 (95% CI: 0.60-0.83), and pooled AUC was 0.85 (95% CI: 0.81-0.88). For internal validation, pooled sensitivity was 0.81 (95% CI: 0.72-0.87) and specificity was 0.86 (95% CI: 0.82-0.90). An exploratory classification-based E/O analysis yielded a pooled E/O ratio of 1.66 (95% CI: 1.07-2.58). E/O ratios greater than 1 were frequently observed, suggesting that AI-positive classifications may have exceeded observed osteoporosis cases in some settings. An exploratory net-benefit approximation suggested positive net benefit for the AI screening model across clinically relevant threshold probabilities (0.05-0.15). AI-based chest radiograph assessment shows promising diagnostic accuracy for identifying individuals who may warrant confirmatory DXA testing. Although exploratory analyses suggested a possible role for AI-assisted triage, its impact on DXA utilization, treatment initiation, fracture prevention, workflow burden, and healthcare system costs remains unproven. Significant performance variability and findings from exploratory classification-based E/O analyses highlight the importance of local validation and careful evaluation of setting-specific performance variability prior to clinical deployment.