Back to all papers

Accelerated Multi-Shot Diffusion-Weighted MRI of the Head and Neck Using Deep Learning Reconstruction.

November 26, 2026pubmed logopapers

Authors

Runkel S,Kronfeld A,Khalaf M,Heiden L,Al Mansour H,Schöffling VI,Paul RH,Wei L,Darwish O,Krüger M,Brockmann MA,Othman AE,Altmann S

Affiliations (5)

  • Department of Neuroradiology, University Medical Center of Johannes Gutenberg University Mainz, Mainz, Germany.
  • Institute of Medical Biostatistics, Epidemiology and Informatics, University Medical Center of Johannes Gutenberg University Mainz, Mainz, Germany.
  • Siemens Healthineers AG, Forchheim, Germany.
  • Department of oral and maxillofacial surgery, University Medical Center of Johannes Gutenberg University Mainz, Mainz, Germany.
  • Department of Neuroradiology, University Medical Center of Johannes Gutenberg University Mainz, Mainz, Germany. [email protected].

Abstract

High-resolution imaging of the head and neck is crucial, with diffusion-weighted imaging (DWI) providing high diagnostic value. Patient-related factors such as comorbidities and difficulty remaining still make shorter scan times desirable while preserving image quality. This study aims to evaluate the feasibility of deep learning-reconstructed DWI for routine head and neck MRI. In this study, two readout-segmented echo-planar imaging (rs-EPI) DWI acquisitions were performed on a 1.5 T scanner in 55 patients undergoing indicated MRI: a sequence reconstructed conventionally (c-DWI) and a prototype deep learning-reconstructed rs-EPI (DL-DWI). Scan time of DL-DWI was decreased by 40%. The datasets were evaluated by three radiologists using a 4-point Likert scale for image quality, diagnostic confidence, pathology assessment, artifacts and anatomical regions. Objective quantitative image analysis evaluated signal intensity (SI), signal-to-noise ratio (SNR), and the ratio of voxels above diagnostic threshold compared to the total number of voxels (NumVox). Fleiss's kappa (ϰ) determined inter-rater agreement. DL-DWI was superior, particularly in image quality, diagnostic confidence, pathology assessment, and evaluation of anatomical regions (p < 0.001). 63.6% of DL-DWI images showed excellent image quality, compared to 7.3% for c‑DWI (p < 0.001). Artifacts were the only parameter for which DL-DWI was not superior. However, readers were confident in classifying artifacts, and DL-DWI showed no false-negative or false-positive findings. Inter-rater agreement was nearly perfect for both, with higher values for DL-DWI. DL-DWI showed significantly higher NumVox and SNR (p < 0.001). DL-DWI markedly improves image quality and acquisition efficiency, reducing scan time by almost 50%.

Topics

Journal Article

Ready to Sharpen Your Edge?