Back to all papers

FOCUS: A Frequency Offset Selection Framework for Accelerated CEST MRI Using Adaptive Subset-Level Optimization.

November 24, 2026pubmed logopapers

Authors

Wu J,Chen Z,Chen X,Jiang X,Lai G,Zhou Y,Huang J,Chen L

Affiliations (4)

  • Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, School of Electronic Science and Engineering, National Model Microelectronics College, Xiamen University, Xiamen, China.
  • Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
  • Department of Diagnostic Radiology, The University of Hong Kong, Hong Kong, China.
  • Shenzhen Research Institute of Xiamen University, Shenzhen, China.

Abstract

To develop a redundancy-aware frequency offset selection framework for accelerated chemical exchange saturation transfer (CEST) MRI that reduces acquired saturation frequency offsets while preserving quantitative and classification performance. FOCUS, a Frequency Offset selection framework for accelerated CEST MRI Using adaptive Subset-level optimization, was developed to account for inter-offset redundancy beyond individual offset importance. Frequency offset selection was formulated as subset-level optimization, in which candidate subsets were encoded as binary individuals and evaluated by final task performance. An artificial protozoa optimizer-based search scheme was used to explore the subset space, and a deep Q-network adaptively guided the search strategy. FOCUS was evaluated in numerical simulations, in vivo human skeletal muscle phosphocreatine quantification, and glioma molecular subtype classification, and compared with permutation importance analysis, random forest, and channel pruning. Under reduced frequency-offset sampling, FOCUS outperformed existing methods in both CEST quantification and glioma molecular subtype classification. For CEST quantification, FOCUS achieved the lowest root mean square error in simulations and in vivo skeletal muscle experiments, with the highest structural similarity index and peak signal-to-noise ratio in vivo. For glioma classification, FOCUS achieved the best overall performance in predicting isocitrate dehydrogenase mutation and O6-methylguanine-DNA methyltransferase promoter methylation status. FOCUS enables redundancy-aware frequency offset selection for accelerated CEST MRI, reducing acquired saturation frequency offsets while preserving quantitative accuracy and classification performance.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.