Back to all papers

A K-space guided invertible diffusion model for accelerating MRI reconstruction.

November 14, 2026pubmed logopapers

Authors

Yang J,Zhu F,Yu Z,Chen Y,Ding J

Affiliations (1)

  • School of Computer, Jiangsu University of Science and Technology, Zhenjiang, China.

Abstract

Magnetic resonance imaging (MRI), a core technology in clinical medical diagnosis, has long aimed to balance imaging quality and acquisition efficiency. Traditional MRI techniques, limited by the Nyquist-Shannon sampling theorem, are faced with significant challenges in high-acceleration-factor imaging, including artifacts and detail loss due to sparse sampling. While existing parallel imaging, compressed sensing, and deep learning methods have improved reconstruction efficiency, they have limitations such as insufficient integration of electromagnetic physics models with biological tissue prior information, inadequate high-frequency information recovery, and high computational complexity. To address these persistent limitations in high-acceleration MRI reconstruction, this study proposes a K-space guided invertible diffusion model (KG-IDM) designed to improve reconstruction fidelity. KG-IDM enables high-quality MRI reconstruction through Cross-domain Feature Injection (CFI) with Adaptive Channel-Spatial Interaction Attention (ACSIA) for multi-source feature alignment, and a K-space Guided Bimodal Spectral Enhancement Network (KG-BSEN) for dual-path frequency-spatial enhancement. This framework jointly exploits spatial and spectral representations, enhancing cross-domain feature consistency and reducing reconstruction artifacts. Experiments on the fastMRI single-coil knee dataset using retrospectively undersampled complex-valued k-space at <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mn>4</mn> <mo>×</mo></mrow> </math> , <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mn>6</mn> <mo>×</mo></mrow> </math> , <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mn>8</mn> <mo>×</mo></mrow> </math> , and <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mn>10</mn> <mo>×</mo></mrow> </math> acceleration show that KG-IDM achieves the highest mean PSNR and SSIM and the lowest mean NMSE relative to all nine baseline methods. At <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mn>4</mn> <mo>×</mo></mrow> </math> acceleration, KG-IDM achieves <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mn>32.05</mn></mrow> </math>  dB PSNR, <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mn>81.35</mn> <mo>%</mo></mrow> </math> SSIM, and <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mn>0.0230</mn></mrow> </math> NMSE. At <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mn>10</mn> <mo>×</mo></mrow> </math> , it achieves <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mn>25.58</mn></mrow> </math>  dB, <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mn>62.55</mn> <mo>%</mo></mrow> </math> , and <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mn>0.0815</mn></mrow> </math> , respectively. Paired volume-level Wilcoxon tests over 199 evaluation volumes showed statistically significant favorable differences in all 108 comparisons, with all Holm-adjusted <math xmlns="http://www.w3.org/1998/Math/MathML"><mrow><mi>p</mi> <mo><</mo> <msup><mn>10</mn> <mrow><mo>-</mo> <mn>4</mn></mrow> </msup> </mrow> </math> . By integrating measurement-guided cross-domain feature fusion with frequency-spatial refinement, KG-IDM consistently improves reconstruction fidelity across the evaluated acceleration factors and provides a promising framework for accelerated MRI reconstruction.

Topics

Image Processing, Computer-AssistedMagnetic Resonance ImagingJournal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.